2
On and Off
Parameter 7: Values of ON command frame sent to Group 2 Association.
The value of 0 turns OFF the device, 255 turns it On. In the case of associating the Dimmer or Roller Shutter module,
values
Size: 1 Byte, Default Value: 255
Setting Description
0 - 99
allow setting an Associated device to a
specified level (0 is OFF)
255
ON
Parameter 8: Value of OFF command frame sent to Group 2 Association.
8 1 0-99,255 0 Value of OFF command frame sent to 2nd Association Group
The value of 0 turns OFF the device, 255 turns it On. In the case of associating the Dimmer or Roller Shutter module,
values.
Size: 1 Byte, Default Value: 0
Setting Description
0 - 99
allow setting an associated device to a
specified level. (0 is OFF)
255
ON
Parameter 9: Time Delay of ON command from Group #2.
The time period after which On command frame will be sent.
Size: 1 Byte, Default Value: 0
Setting Description
0 -
32400
Time set in seconds
Parameter 10: Time Delay of OFF command from Group #2.
The time period after which the OFF command frame will be sent.
Size: 1 Byte, Default Value: 0
Setting Description
0 -
32400
Time in seconds
Parameter 11: Delay of tamper alarm cancellation.
The time period after which a tamper alarm will be canceled.
Size: 1 Byte, Default Value: 0
Setting Description
0 -
32400
Time in seconds
Parameter 12: Reporting tamper alarm cancellation.
Reporting cancellation of tamper alarm to the controller and 3rd Association Group.
Size: 1 Byte, Default Value: 1
Setting Description
0
do not send tamper cancellation report
1
send tamper cancellation report
Parameter 13: Central Scene Event functionality.
Enable/Disable Central Scene Events.
Size: 1 Byte, Default Value: 0