background image

 

Page 4 

 

Security 

Supported 

Command 

Class List 

 

COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_POWERLEVEL_V1 

COMMAND_CLASS_NOTIFICATION_V7 

COMMAND_CLASS_BATTERY_V1 

COMMAND_CLASS_SENSOR_MULTILEVEL_V5 

COMMAND_CLASS_CONFIGURATION_V1 

COMMAND_CLASS_MULTI_CHANNEL_V4 

COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATI

ON_V3 

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 

 

 

2.

 

Technical Specifications  

Operating distance

: Up to 492feet/150 meters outdoors.  

 

3.

 

Familiarize yourself with your Water Sensor

 

3.1 Interface 

 

 

 

 

 

4.

 

All Functions of Each Trigger  

4.1

 

Function of Action Button 

Trigger 

Description 

Click one time 

1.

 

Send non-security Node Info frame. 

2.

 

Add Water Sensor into Z-Wave network(non-security inclusion): 

Содержание Aeotec Water Sensor 6

Страница 1: ...Page 1 Aeon Labs Water Sensor 6 Z Wave Water Sensor...

Страница 2: ...Page 2 Change history Revision Date Change Description 1 01 05 2017 Initial draft 2 03 28 2017 Update 3 04 07 2017 Update 4 04 27 2017 Update...

Страница 3: ...mware upgrade As soon as Water Sensor 6 is removed from a Z Wave network it will be restored into default factory setting 1 Library and Command Classes 1 1 SDK 6 51 09 1 2 Library Basic Device Class B...

Страница 4: ...TION_V1 COMMAND_CLASS_MULTI_CHANNEL_V4 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATI ON_V3 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 2 Technical Specifications Operating distance Up to 492feet 150 meters outdoors 3...

Страница 5: ...slowly when you short press the Action Button 2 Let the primary controller into inclusion mode If you don t know how to do this refer to its manual 3 Press the Action Button 4 If the inclusion is succ...

Страница 6: ...VEPLUS_NODE Installer Icon Type 0x0C07 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY User Icon Type 0x0C07 ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_HOME_SECURITY 5 3 Manufacturer Specific Report...

Страница 7: ...C 28 4C 65 61 6B 20 50 72 6F 62 65 20 32 29 5 5 2 Association Group Info Report Group Profile Vg1 Group 1 General Lifeline 01 01 00 00 01 00 00 00 Group 2 General NA 01 02 00 00 00 00 00 00 Group 3 No...

Страница 8: ...ed report to the associated nodes in association Group 3 when the sensor probe 1 is triggered 2 Multi Channel endpoint 2 capability 71 COMMAND_CLASS_NOTIFICATION 5E COMMAND_CLASS_ZWAVEPLUS_INFO 59 COM...

Страница 9: ...to OFF state 0x001E0A0A 4 0x27 39 Set the low battery value Range 10 to 50 20 1 0x30 48 Enable disable the sensor report Bit 0 the corresponding sensor report is disabled Bit 1 the corresponding sens...

Страница 10: ...86 Enable disable the buzzer 0 disable 1 enable 1 1 0x57 87 To set which sensor is triggered the buzzer will alarm 1 If the Water leak is triggered the buzzer will alarm 2 If the vibration is trigger...

Страница 11: ...sensor probes status through this configuration value If Bit 0 0 which means absence of water is triggered by probe 1 If Bit 0 1 which means presence of water is triggered by probe 1 If Bit 1 0 which...

Страница 12: ...ult setting N A 1 Parameter number equals 0x30 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 _ _ Notification Report for Overheat alarm Notification Report for Under heat alarm _ Configuration Repor...

Отзывы: