background image

 

 

AEOEZW100 
Routing Multisenor

 

Firmware Version : 1.4 

 

Quick Start 

A

 This is a Z-Wave actuator. 

Power on the MultiSensor. The MultiSensor’s LED will blink slowly when you short press the Action Button. Set the primary controller into 
inclusion mode (If you don’t know how to do this, refer to its manual). Press the Action Button. If the inclusion is successful, the 
MultiSensor’s LED will be kept turning on for 8 seconds when you short press the Action Button. If the LED is still in slow blink, you need to 
repeat the process from setting the controller into inclusion mode onward. 

Please refer to the chapters below for detailed information about all aspects of the products usage. 

What is Z-Wave? 

This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the 

international standard for 

wireless communication

 in smart homes and buildings. It is using the 

frequency of 868.42 MHz

 to realize a very stable and secure 

communication. Each message is reconfirmed (

two-way communication

) and every mains powered node can act as a repeater for other 

nodes (

meshed network

) in case the receiver is not in direct wireless range of the transmitter. 

Содержание AEOEZW100

Страница 1: ...link you need to repeat the process from setting the controller into inclusion mode onward Please refer to the chapters below for detailed information about all aspects of the products usage What is Z...

Страница 2: ...ontrollers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers Product description Aeon Labs MultiSensor is a rou...

Страница 3: ...xclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exc...

Страница 4: ...and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame There are 2 ways to s...

Страница 5: ...s when re power on battery mode the MultiSensor Value Description 0 disable Default 1 enable default PIR time Parameter Number 3 Parameter Size 2 The default PIR time is 4 minutes The Multisensor will...

Страница 6: ...orting Parameter Number 40 Parameter Size 1 Enable disable the selective reporting only when measurements reach a certain threshold or percentage set in 41 44 below This is used to reduce network traf...

Страница 7: ...Size 1 The battery activity will be reduced at low temperatures 15 degrees Celsius and below which will lead to the product may not work normally It is recommended to use USB power at low temperatures...

Страница 8: ...reserved 2 0 7 reserved 3 0 7 reserved 4 0 Battery 1 3 reserved 4 ultraviolet 5 temperature 6 Humidity 7 Luminance Set 111 113 to default Parameter Number 110 Parameter Size 1 Value Description Param...

Страница 9: ...e Meta Data version 2 Battery version 1 Association version 2 Device Reset Locally version 1 Controlled Command Classes Device Reset Locally version 1 Technical Data Battery Type 2 CR123A Explorer Fra...

Страница 10: ...twork Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able...