Aeon Labs AEO HEM2-100A Скачать руководство пользователя страница 9

Value Description

0

Seconds

Partner ID (Parameter Number 200, Parameter Size 1) (0= Aeon Labs Standard Product, 1= AT&T).

Value Description

Enable/disable Configuration Locked (Parameter Number 252, Parameter Size 1) 0 =disable, 1 = enable

Value

Description

0

0 = disabled (Default)

1

1 = enabled

Device Tag (Parameter Number 254, Parameter Size 2) 

Value Description

Reset (Parameter Number 255, Parameter Size 1) Reset configuration set up to default setting

Value Description

Command Classes

Supported Command Classes

Multi Channel (version 3)

Basic (version 1)

Association (version 1)

Version (version 1)

Meter (version 3)

Configuration (version 1)

Manufacturer Specific (version 2)

Technical Data

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 9 

Содержание AEO HEM2-100A

Страница 1: ...ize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute ...

Страница 2: ...ill report that energy use back to your control point in watts or kilowatt hours and in real time So you can see how much electricity you really use and when you use it The main body is anchored using a back mount The device is powered from a normal AC power supply The device has two clamps and reports W and kWH up to 100 Ampere Before Device is installed Please read carefully the enclosed user ma...

Страница 3: ... wires protruding from the bottom of the unit To place the Home Energy Meter Slip open the backing plate from the back of your meter Affix the plate to the selected wall space using the provided screws Attach your meter to the backing plate After an electrician connects your Home Energy Meter to your electrical mains you should include the meter into your Z Wave network Behavior within the Z Wave ...

Страница 4: ...l a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 Receiver of all R...

Страница 5: ...end Report Watt for clamp 1 Parameter Number 5 Parameter Size 2 The value represents the minimum change in Wattage for a Report to be sent Value Description 0 32000 W Default 50 Minimum Change to send Report Watt for clamp 2 Parameter Number 6 Parameter Size 2 The value represents the minimum change in Wattage for a Report to be sent Value Description 0 32000 W Default 50 Minimum Change to send Re...

Страница 6: ...meter Size 1 The value represents the minimum change in Watage Percent for a report to be sent Value Description 0 255 Default 10 Minimum Change to send Report for clamp 3 Parameter Number 11 Parameter Size 1 The value represents the minimum change in Watage Percent for a report to be sent Value Description 0 255 Default 10 Enable disable reporting CRC 16 Encapsulation Command Parameter Number 13 ...

Страница 7: ...lamp 2 8192 Meter Report for kWh for clamp 3 Report Type send in Reporting Group 2 Parameter Number 102 Parameter Size 4 Defines the type of report sent for the Reporting Group 2 Value Description 1 Battery Report 2 MultiSensor Report for the whole device 4 Meter Report for Watt for the whole device 8 Meter Report for kWh for the whole device 256 Meter Report for Watt for clamp 1 512 Meter Report ...

Страница 8: ... to default Parameter Number 110 Parameter Size 1 Value Description Send Interval for Reporting Group 1 Parameter Number 111 Parameter Size 1 Defines the time interval when the defined report of Reporting Group 1 is sent out Value Description 0 255 Seconds Default 1 Send Interval for Reporting Group 2 Parameter Number 112 Parameter Size 1 Defines the time interval when the defined report of Report...

Страница 9: ...ameter Number 254 Parameter Size 2 Value Description Reset Parameter Number 255 Parameter Size 1 Reset configuration set up to default setting Value Description Command Classes Supported Command Classes Multi Channel version 3 Basic version 1 Association version 1 Version version 1 Meter version 3 Configuration version 1 Manufacturer Specific version 2 Technical Data c 2012 Z Wave Europe GmbH Gold...

Страница 10: ...inging new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device t...