Parameters

Choosing The Working 

Space For The Unit

≥15cm

The unit should be used indoors only, in a cool 

dry room with stable temperature and humidi-

ty, kept out of direct sunlight, away from any 

heat sources, excess moisture or naked 

flames.

This unit should only be operated in a 

temperature range of 10° to 40° C (50° to 103° 

F). It should not be placed in the direct path of 

a room air conditioning outlet. 

The full unit weighs 300 kg (660lbs); it should 

be placed on a level stable floor.

It should never be placed on a soft or uneven 

surface like bedding materials or shaggy 

carpets. 

The unit should be placed in a well-ventilated 

position, and all inlets and outlets should be 

unobstructed, there should be a 15cm or 

6-inch clearance on all sides.

Care should be taken when choosing the working space for this unit. 

Product Name

Model Number

Dimension

Weight

Power Supply

Environment 

Control

Air Purification

Temperature 

Setting Range 

Oxygen Concen-

tration Setting

Carbon Dioxide 

Monitoring and 

Removal

Alarms

Dehumidification

8.4”, 171mmW×128mmH

Resistive

1.3KW

0.5KW

Emergency Ventilation Port

7.2×106pcs/cm3      

Negative Ion Generator

Smart Control Needle Type Printer

253nm UV Sterilization

415nm Blue Therapeutic Light  

Treatment

≥0.2ml/min, particle size: 

0.5 -2μm, noise≤ 40dB(A)

Control Panel

Screen Type

Max. Power 

Consumption 

Average Power 

Consumption

Power Supply 

Failure Protection

Negative Ion 

Generator

Accessories 

Built-in Printer

Ultra-violet 

Sterilization

Blue Light 

Therapy

Medical 

Nebulizer

LED Illumination

Ventilation Fan 

Control

Professional Veterinary 

Intensive Care Unit

UC-1901M/L/BK

1509mmW×884mmD×1899mmH 

(59.5”W×35”D ×75”H)

Approximate 300kg (660lbs)

AC100

120V /220

240V

50/60Hz (Grounded)

4 Compartments Controlled 

Separately, Cooling and Heating. 

Two Medium Compartments on 

Top Tier, One Large Compartment 

on Bottom Tier which could be 

divided into two medium com-

partments when needed.

Ultra Violet Sterilization, High 

Concentration Negative Ion Air 

Purification.

-10

40°C (Indoor)

15

38°C, Tolerance at 0.5°C

21

65%, Tolerance at ±1%.

200 -5000PPM, 

Tolerance at ±10PPM, 

Built-in CO2 Sensor and Remover

Automatic Dehumidification, 

High/Middle/Low Three Stages, 

High: 45%

50%, 

Middle: 40%

44%, 

Low: 30%

39%.

O2 Concentration Alarm, Tempe-

rature Alarm, Sensor Alarm, Door 

Opening Alarm, CO

2

 

Concentration. 

Alarm, Emergency Ventilation Port 

Malfunction Alarms.

Soda Lime CO2 Absorption 

Powder, Equipment Mount Grid, 

Door Shade Curtain.

Working 

Condition

Low/Middle/High, Three-Stage Speed 

Control.

Defaults:

Oxygen Input On: Low Speed.

Temperature Control: High Speed

Emergency Port Open: High Speed

Ultra-violet Sterilization On: Middle

CO2 Concentration Level Alarm On: 

High

Pure White Cold Light for 

Examination, 10 Stage Adjustable 

Yellow .

Comfort Light for Illumination.

Содержание UC-1901BK

Страница 1: ...Distributor Contacts UC 1801 KO2 10F KO2 2F UC 1901 Professional Multifunctional Veterinary Intensive Care Unit WMS 1501 Professional Vet Equipments Supplier User Manual...

Страница 2: ...dimensions General usage guidelines General opreation tips Radio requency interferece Choosing the working space for the unit Parameters Operation guidance Setting interface Setting mode Trouble shoo...

Страница 3: ...ge caused by a third party Transport or Delivery Company The day the unit is delivered an inspection of the outer packing should be made for any damage to the packing box Then the unit should be unpac...

Страница 4: ...dB A Control Panel Screen Type Max Power Consumption Average Power Consumption Power Supply Failure Protection Negative Ion Generator Accessories Built in Printer Ultra violet Sterilization Blue Light...

Страница 5: ...and displays 1 Setting Mode Allows the operator to switch on off and set all the changeable running parameters for most functions 2 Operating History Allowing the operator to view a complete operatio...

Страница 6: ...rbon dioxide figure in CO2 Density bar c Input the desired carbon dioxide density by clicking the newly displayed setting box within the range of 200 2000ppm d Click Enter to set the new carbon dioxid...

Страница 7: ...ight Therapy Exam Light Emergency Vent Se ng Blue Light Therapy MIDDLE 12 Nebulizer and Timer a Open the nebulizer chamber door on front control panel of the machine b Gently take the nebulizer assemb...

Страница 8: ...er reminder In box 4 it shows the elapsed working time from last replacement box 2 is for resetting the validation time for different suppliers soda lime If you are using the soda lime from our compan...

Страница 9: ...and right compartments will start to operate 1 Temperature Sensor Humidity Sensor Replacement Both Temperature and humidity sensors can be found can be found at the innermost top corner of the compart...

Страница 10: ...he top cover on ICU compartment to expose internal components Please find the negative ion generator check if it s broken Open and remove the protective cover on the emergency ventilation fan on the b...

Отзывы: