Statement of Compliance

Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments 

certifies that this instrument has been calibrated 
using standards and instruments traceable to 
international standards.

We guarantee that at the time of shipping your 
instrument has met its published specifications.

An NIST traceable certificate may be 
requested at the time of purchase, or obtained 
by returning the instrument to our repair and 
calibration facility, for a nominal charge.

The recommended calibration interval for this 
instrument is 12 months and begins on the date of 
receipt by the customer.  

Serial #: 

 ________________________________

Catalog #: 

 

2115.82

Model #:   MN261

Please fill in the appropriate date as indicated:

Date Received:  _________________________________

Date Calibration Due: 

 _______________________

Chauvin Arnoux

®

, Inc.

d.b.a AEMC

®

 Instruments

www.

ShopAEMC

.com

Shop for AEMC products online at:

1.888.610.7664

Содержание MN261

Страница 1: ...URRENT OSCILLOSCOPE PROBE MN261 E N G L I S H User Manual OUTPUT 20 A Range 100 mV AAC 200 A Range 10 mV AAC 200A 20 A MN 261 AC CURRENT PROBE www ShopAEMC com Shop for AEMC products online at 1 888 610 7664 ...

Страница 2: ...rchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer Serial _________________________________ Catalog 2115 82 Model MN261 Please fill in the appropriate date as indicated Date Received __________________________________ Date C...

Страница 3: ...4 2 1 Description 4 2 2 Compatibility 4 2 3 Control Features 5 3 SPECIFICATIONS 6 3 1 Electrical Specifications 6 3 2 Mechanical Specifications 7 3 3 Environmental Specifications 7 3 4 Safety Specifications 7 3 5 Typical Response Curves 8 4 OPERATION 10 4 1 Current Measurement 10 5 MAINTENANCE 11 5 1 Maintenance 11 5 2 Cleaning 11 Limited Warranty 13 Warranty Repairs 13 www ShopAEMC com Shop for A...

Страница 4: ...s these should be free of dirt rust or other foreign matter Do not use a probe which is cracked damaged or has defec tive leads 1 1 International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation Use only specified replacement parts when servicing the instrument This symbol on the instrument indicates a WARNING and that the operator must r...

Страница 5: ... Cat IV For measurements performed at the primary electrical supply 1000V such as on primary overcurrent protection devices ripple control units or meters 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If the equip ment appears to be damaged file a claim immediately with the carr...

Страница 6: ...rrent derating without break ing into the circuit A passive filter eliminates noise ring on rapid rising di dt waveforms and ensures accurate screen displays The probe connects directly to an oscilloscope through an insulated coax ial cable with an insulated BNC 2 2 Compatibility The Model MN261 is compatible with any analog or digital oscilloscope or other voltage measuring instrument which has t...

Страница 7: ...m 1 18 30 mm 1 2 3 4 5 1 Jaw Opening 0 83 21mm 2 Maximum dimension of conductor 0 78 20mm 3 Two position switch 4 6 5 ft 2m output cable 5 Arrow indicates direction of current flow Current flows in a positive direction when it travels from supply to load www ShopAEMC com Shop for AEMC products online at 1 888 610 7664 ...

Страница 8: ... 100 to 240A Accuracy 3 5 5mV 3 5mV 2 5 5mV 1 5 5mV Phase Shift N A 6 4 3 Overload 240A for 10mn ON 30mn OFF Range 100mV A 2V at 20A Overload 120A continuous Accuracy 2 50mV Phase Shift not specified Frequency Range with current derating 40Hz to 10kHz 3dB See Typical Response Curves 3 5 Load Impedance 100kΩ min Working Voltage 600V Cat III Common Mode Voltage 600V Cat III Influence of Adjacent Con...

Страница 9: ... 40 to 70 C Influence of Temperature 0 15 10K Influence of Humidity 10 to 90 0 2 Altitude 2000m 3 4 Safety Specifications Indoor Use Electrical Double insulation or reinforced insulation between the primary or second ary and the outer case of the handle per EN 61010 2 032 Common Mode Voltage 600V Category III Pollution Degree 2 Dielectric Strength 5550V 50 60Hz between primary secondary and the ou...

Страница 10: ...0 10 00 100 00 1000 00 10000 00 100000 00 15 00 20 00 25 00 10 00 5 00 0 00 5 00 10 00 15 00 10 00 100 00 1000 00 10000 00 100000 00 Accuracy vs Frequency Phase Shift vs Frequency Frequency in Hz Frequency in Hz Accuracy in Phase in 100 A 200 A 100 A 200 A www ShopAEMC com Shop for AEMC products online at 1 888 610 7664 ...

Страница 11: ...100 00 1000 00 10000 00 100000 00 10 00 20 00 40 00 30 00 10 00 0 00 10 00 20 00 30 00 40 00 100 00 1000 00 10000 00 100000 00 Accuracy vs Frequency Phase Shift vs Frequency Frequency in Hz Frequency in Hz Accuracy in Phase in 10 A 20 A 10 A 20 A www ShopAEMC com Shop for AEMC products online at 1 888 610 7664 ...

Страница 12: ...rectly on your oscilloscope Remember to unclamp the probe from the conductor before disconnect ing it from your meter or instrument You may also use your oscilloscope to amplify the signal while using the 1mV A probe range which offers the best accuracy and least phase shift NOTE It is possible to change the range on the current probe with out removing the probe from the current carrying conductor...

Страница 13: ...ign substances into the case Disconnect the unit from all circuits and test cables before open ing the case Use caution with metallic tools that may short battery packs power supplies etc 5 2 Cleaning To clean the probe body use a soft cloth dampened in a solution of mild detergent and water To clean the core open the jaw and clean the exposed core surfaces with a cotton swab dampened with isoprop...

Страница 14: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664 ...

Страница 15: ...ided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by fax from our Service Department see address below then return the instrument along with the ...

Страница 16: ...08 13 99 MAN 100144 v6 Chauvin Arnoux Inc d b a AEMC Instruments www ShopAEMC com Shop for AEMC products online at 1 888 610 7664 ...

Отзывы: