background image

MiniFlex

®

 Flexible AC Current Probe

 

5

 

CHAPTER 2

PRODUCT FEATURES

2.1 Description

The MiniFlex

®

 is a compact flexible AC current transformer composed of 

a flexible sensor and an electronic module. The flexible sensor permits 

measurements on conductors where standard clamp-on probes could not 

be used. In particular, it can be installed in confined spaces, places where 

access is difficult, or even wrapped around irregular shapes.
The MiniFlex

®

 is lightweight. It does not use magnetic cores like standard 

transformers. The transformation principle is based on an air core. It pres-

ents virtually no load to the system under test, has a low phase shift and 

excellent frequency response, and cannot be damaged by overloads. The 

sensor assembly is insulated for 1000V CAT III; 600V CAT IV. The Mini-

Flex

®

 meets EN 61010 and is CE marked.

The  MiniFlex

®

  has  an  mV  output  proportional  to  the  current  measured 

for direct readings on DMMs, data loggers, oscilloscopes, and power or 

harmonic meters. TRMS measurements are taken when connected to a 

TRMS meter. The MiniFlex

®

 is insensitive to DC currents and only the AC 

component of the measured signal is measured.
The flexible sensor is available in lengths of 6" and 10".

Shop for Data Logging products online at:   

www.

DataLoggerStore

.ca   

1.800.561.8187

Содержание MiniFlex MF 300-6-2-10

Страница 1: ...FLEXIBLE AC CURRENT SENSOR MiniFlex MF 300 6 2 10 MF 3000 10 2 1 E N G L I S H User Manual Shop for Data Logging products online at www DataLoggerStore ca 1 800 561 8187...

Страница 2: ...eturning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the custo...

Страница 3: ...Error Model MF 300 6 2 10 10 3 1 2 Amplitude Error Model MF 3000 10 2 1 11 3 1 3 Phase Error Model MF 300 6 2 10 12 3 1 4 Phase Error Model MF 3000 10 2 1 13 3 1 5 Frequency Limitation Versus Amplitu...

Страница 4: ...and currents may be present and may pose a shock hazard Read the safety specifications section prior to using the current probe Never exceed the maximum voltage ratings given ALWAYS de energize the ci...

Страница 5: ...e Low Voltage Electromagnetic Compatibility European directives 73 23 CEE 89 336 CEE In the European Union this product is subject to a separate collection system for recycling electrical and electron...

Страница 6: ...otify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim 1 4 Ordering Information MiniFlex Model MF 300 6 2 1 Cat 2126 8...

Страница 7: ...iple is based on an air core It pres ents virtually no load to the system under test has a low phase shift and excellent frequency response and cannot be damaged by overloads The sensor assembly is in...

Страница 8: ...verrange LED for measurement circuitry EN 61010 1000V CAT III 600V CAT IV CE Mark 9V battery for typical 140 hour continuous operation 20kHz frequency response Low phase shift for power measurements I...

Страница 9: ...nsor opening device 3 Shielded cord 4 BNC output connector 5 Red OL overload indicator 6 Green ON OFF indicator 7 Range selection switch Model MF 300 6 2 10 30 300A Model MF 3000 10 2 1 300 3000A 8 BN...

Страница 10: ...1 5 typical 3 max Influence Of Conductor Positioning In Sensor Against Handle 4 typical 6 max External Conductor Influence 35dB to 40dB on contact Accuracy 1 0 25A Common Mode Rejection 100dB typical...

Страница 11: ...C 68 2 27 Weatherproofing IP 50 ENVIRONMENTAL Operating Temperature Range 14 to 131 F 10 to 55 C Storage Temperature Range 40 to 158 F 40 to 70 C Influence of Temperature Sensor 10 to 100 C 0 5 of Rea...

Страница 12: ...Curves 3 1 1 Amplitude Error Model MF 300 6 2 10 30A Range 10 0 10 20 30 1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz 300A Range 10 0 10 20 30 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz Shop for Da...

Страница 13: ...Amplitude Error Model MF 3000 10 2 1 300A Range 2 1 0 1 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz 3000A Range 1 0 1 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz Shop for Data Logging products onli...

Страница 14: ...odel MF 300 6 2 10 300A Range 60 50 40 30 20 10 0 10 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz 3000A Range 60 50 40 30 20 10 0 10 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz Shop for Data Logging...

Страница 15: ...Model MF 3000 10 2 1 300A Range 30 25 20 15 10 5 0 5 10 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz 3000A Range 20 15 10 5 0 5 10 1 10 100 1000 10000 100000 Hz Hz Hz Hz Hz Hz Shop for Data Logging p...

Страница 16: ...Probe 3 1 5 Frequency Limitation Versus Amplitude 3000A Range 0 A 500 A 1000 A 1500 A 2000 A 2500 A 3000 A 3500 A 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz Shop for Data Logging products online at www D...

Страница 17: ...the range that provides the best resolution Failure to do this may result in measurement errors For best results select the highest MiniFlex output signal possible and the most sensitive meter range...

Страница 18: ...not use on selected range if overload LED goes on Read the displayed value on the multimeter and divide it by the range selected i e if reading 2 59V with the 10mV A output range the cur rent flowing...

Страница 19: ...on Disconnect everything connected to the instrument and set the switch to OFF Use a screwdriver to unscrew the two screws on the housing Replace the old battery with a new one 9V alkaline or lithium...

Страница 20: ...Shop for Data Logging products online at www DataLoggerStore ca 1 800 561 8187...

Страница 21: ...tration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an Instrument for Warranty Repa...

Страница 22: ...Notes Shop for Data Logging products online at www DataLoggerStore ca 1 800 561 8187...

Страница 23: ...Shop for Data Logging products online at www DataLoggerStore ca 1 800 561 8187...

Страница 24: ...08 13 99 MAN 100345 v4 Chauvin Arnoux Inc d b a AEMC Instruments Shop for Data Logging products online at www DataLoggerStore ca 1 800 561 8187...

Отзывы: