FlexProbe

®

 - Flexible AC Current Probe

Table of Contents

1. INTRODUCTION ............................................................................... 3

1.1  International Electrical Symbols ................................................3

1.2  Definition of Measurement Categories

 .....................................4

1.3  Receiving Your Shipment

 ..........................................................4

1.4  Ordering Information

 .................................................................4

1.4.1  Accessories and Replacement Parts

 ............................4

2.  PRODUCT FEATURES ...................................................................... 5

2.1  Description

 ................................................................................5

2.2  General Features

 ......................................................................6

2.3 FlexProbe

®

 24-3001 Features

 ..................................................7

3. SPECIFICATIONS............................................................................. 8

3.1 Electrical ...................................................................................8
3.2 Environmental ...........................................................................9

3.3  Mechanical Specifications

 ........................................................9

3.4  Safety Specifications

 ..............................................................10

4. OPERATION .................................................................................. 11

4.1  Making Measurements with the FlexProbe

®

 ...........................11

4.2  Tips for Making Precise Measurements

..................................12

5. MAINTENANCE ............................................................................. 14

Warning

 ...........................................................................................14

5.1  Changing the Battery

 ..............................................................14

5.2  Cleaning

 ..................................................................................14

Limited Warranty ...................................................................................16

Warranty Repairs

 ...................................................................................16

www.

ShopAEMC

.com

Shop for AEMC products online at:

1.888.610.7664

Содержание FlexProbe 24-3001

Страница 1: ...IBLE AC CURRENT PROBE FlexProbe 24 3001 E N G L I S H User Manual I N S T R U M E N T S CAT III 1000V 300A 3000A OFF ON OL FlexProbe 24 3002 www ShopAEMC com Shop for AEMC products online at 1 888 610...

Страница 2: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Страница 3: ...hase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of...

Страница 4: ...2 1 Description 5 2 2 General Features 6 2 3 FlexProbe 24 3001 Features 7 3 SPECIFICATIONS 8 3 1 Electrical 8 3 2 Environmental 9 3 3 Mechanical Specifications 9 3 4 Safety Specifications 10 4 OPERAT...

Страница 5: ...ct the module sensor sensor cable and output termi nals prior to use Replace any defective parts immediately Use only factory parts NEVER use the FlexProbe on electrical conductors rated above 1000V C...

Страница 6: ...y overcurrent protection devices ripple control units or meters 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consis tent with the packing list Notify your d...

Страница 7: ...typically associated with flexible sensors The FlexProbe is lightweight It does not use magnetic cores like standard transformers The transformation principle is based on an air core It pres ents virt...

Страница 8: ...nge LED for measurement circuitry EN 61010 1000V CAT III 600V CAT IV Waterproof sensor 9V battery for typical 150 hour continuous operations Shape Memory for custom pre shaping of sensor before use no...

Страница 9: ...robe 24 3002 1 2 3 6 4 5 8 7 1 Flexible sensor 0 5 12 5mm 2 Range selection switch 3 Power ON indicator Green LED 4 Overload indicator Red LED 5 Electronic module 6 Double insulated 14 36cm lead with...

Страница 10: ...r 1 of Reading 500mA Crest Factor 4 5 Phase Shift 0 7 at 50 or 60Hz Frequency Range 40 to 5kHz Residual Noise When I Measured 0 200mArms Working Voltage 1000Vrms CAT III 600V CAT IV Common Mode Voltag...

Страница 11: ...Sensor 24 1 610 x 25mm Color Sensor Red with black connector Dimensions Electronic Module 4 9 x 2 5 x 1 1 124 x 64 x 28mm Color Electronic Module Dark gray Weight 1 1 lb 0 5kg Output Double insulated...

Страница 12: ...dle per EN 61010 EN 61010 1000V CAT III 600V CAT IV Pollution Degree 2 Electromagnetic Compatibility EN 50081 1 Class B EN 50082 2 Electrostatic discharge IEC 1000 4 2 Radiated Field IEC 1000 4 3 Fast...

Страница 13: ...eed specified current range for the output Do not use on selected range if Overload LED goes on 4 Example a Read the DMM displayed value 2 59V b Determine the range and output used on the FlexProbe 0...

Страница 14: ...on and accuracy when measuring low mVAC For best accuracy center the FlexProbe around the conductor to be measured To increase the sensitivity or measure on low cur rents the FlexProbe may be wrapped...

Страница 15: ...nge 250A I N S T R U M E N T S CAT III 1000V 300A 3000A OFF ON OL FlexProbe 24 3002 ACV DCV COM 250 0MV I N S T R U M E N T S CAT III 1000V 300A 3000A OFF ON OL FlexProbe 24 3002 Double the turns to d...

Страница 16: ...n page 2 5 1 Changing the Battery If the power ON indicator green LED blinks or does not light up replace the battery Disconnect the instrument from any source of electricity To replace the battery op...

Страница 17: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Страница 18: ...we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an I...

Страница 19: ...www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Страница 20: ...01 15 99 MAN 100272 v8 Chauvin Arnoux Inc d b a AEMC Instruments www ShopAEMC com Shop for AEMC products online at 1 888 610 7664...

Отзывы: