background image

4

 

Infrared Thermometer Model CA879

1.2  Definition of Measurement Categories

CAT I:  

Measurement category I corresponds to measurements taken on circuits 

not directly connected to the network.

CAT II:

  Measurement category II corresponds to measurements taken on cir-

cuits directly connected to the installation.

 

Example: 

measurement for electrodomestic units, portable tools and 

analogue devices

CAT III:

  Measurement  category  III  corresponds  to  measurements  on  building 

installations.

 

Example: 

measurement on distribution panels, cabling, etc.

CAT IV:

  Measurement category IV corresponds to measurements taken at the 

source of low-voltage installations

 

Example:

 metering and measurements on overvoltage protection de-

vices.

1.3  Receiving Your Shipment

Upon receiving your shipment, make sure that the contents are consistent with the 

packing list. Notify your distributor of any missing items. If the equipment appears 

to be damaged, file a claim immediately with the carrier and notify your distributor 

at once, giving a detailed description of any damage. Save the damaged packing 

container to substantiate your claim.

1.4  Ordering Information

Infrared Thermometer Model CA879

.............................................

Cat. #2121.37

Includes soft carrying case, 9V battery and a user manual.

1.4.1  Accessories and Replacement Parts

Soft Carrying Case

 .........................................................................

Cat. #2121.57

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание CA879

Страница 1: ...CA879 INFRARED THERMOMETER E N G L I S H User Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...nstrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer For recali...

Страница 3: ...ERATION 8 4 1 Precautions for use 8 4 2 Ratio Between Distance from Target Diameter of Measurement Field 8 4 3 Operating Test 9 4 4 Operating Procedure 9 5 MAINTENANCE 10 5 1 Maintenance 10 5 2 Cleani...

Страница 4: ...Symbols Signifies that the instrument is protected by double or reinforced insulation This symbol on the instrument indicates a WARNING that the operator must refer to the user manual for instruction...

Страница 5: ...taken at the source of low voltage installations Example metering and measurements on overvoltage protection de vices 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the conten...

Страница 6: ...ons at the speed of light When the gun is pointed at an object the probe s lens senses this energy and focuses it onto an infrared detector comprised of a thermocouple stack The detector produces a vo...

Страница 7: ...tons 3 Laser button 4 Laser pointer beam 5 IR Sensor 6 Measurement trigger 7 Battery cover 8 Measurement indication 9 Data hold indication 10 Low battery indication 11 Laser beam ON indication 12 Fixe...

Страница 8: ...550 C 5 C of 50 to 20 C Emissivity Preset at 0 95 Spectral response 6 to 14 m Response time 400ms Laser 1mW 670nm type Power supply 9V battery 6LR61 or 6LF22 MECHANICAL Dimensions 9 05 x 3 93 x 2 20...

Страница 9: ...the lens at the measurement opening as it may be obscured by condensation or particles If so clean it by carefully following the instructions in 5 4 2 Ratio Between Distance from Target Diameter of M...

Страница 10: ...R and BACKLIGHTING buttons 3 Select a measurement unit 4 Point the thermometer at the object whose temperature you wish to measure with or without using the LASER target 5 Press the trigger to measure...

Страница 11: ...pe with a damp cloth and then dry with a dry cloth Never use alcohol solvents or hydrocarbons 5 2 2 Cleaning the Lens Remove the dust using a clean rubber dust removing bulb Carefully remove any remai...

Страница 12: ...write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T Includes c...

Страница 13: ...have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material Warranty Repairs What you must do to return an Inst...

Отзывы: