Power Quality Analyzer PowerPad

®

 IV Model 8345 Quick Start Guide 

5

Thank you for purchasing an 

AEMC

®

 Instruments PowerPad

®

 IV Model 8345

.

For best results from your instrument and for your safety, read the enclosed 

operating instructions carefully and comply with the precautions for use. 

Only qualified and trained operators should use this product.

Symbols

CAUTION - Risk of Danger!

 Indicates a 

WARNING

. Whenever this symbol 

is present, the operator must refer to the user manual before operating the 

instrument in all cases where this symbol is present
Indicates a risk of electric shock. The voltage at the parts marked with this 

symbol may be dangerous

USB socket

Kensington anti-theft lock

Ethernet connector (RJ45)

Ground/Earth

Indicates important information to acknowledge

SD card

This product has been declared recyclable following an analysis of the life 

cycle in accordance with standard ISO 14040
This product complies with the Low Voltage & Electromagnetic Compatibility 

European directives (73/23/CEE & 89/336/CEE)
In the European Union, this product is subject to a separate collection system 

for recycling electrical and electronic components in accordance with directive 

WEEE 2002/96/EC

 

Definition of Measurement Categories (CAT)

CAT IV 

corresponds to measurements at the source of low-voltage installations.

Example: power feeders, counters, and protection devices

CAT III 

corresponds to measurements on building installations.

Example: distribution panel, circuit-breakers, machines, and fixed industrial devices

CAT II 

corresponds to measurements on circuits directly connected to  

low-voltage installations.

Example: power supply to domestic electrical devices and portable tools

Содержание 8345

Страница 1: ...PowerPad IV Model 8345 Quick Start Guide ENGLISH POWER QUALITY ANALYZER WITH AEMC INSTRUMENTS Class A POWERP D IV POWERP D IV...

Страница 2: ...rtificate may be requested at the time of purchase or obtained by returning the instrument to our repair and calibration facility for a nominal charge The recommended calibration interval for this ins...

Страница 3: ...2140 43 1 5 ft USB Cable Cat 2140 46 1 5 8 A h 64 W h Li ion Battery Pack Cat 2960 47 1 1000 V PA32ER Power Supply Includes Power Plug Adapter Cat 5100 15 PowerPad IV Model 8345 12 Color coded ID Mark...

Страница 4: ...Color coded ID Markers Cat 2140 45 Also included 1 Quick Start Guide 1 SD Card 1 USB Drive with user manual and application software 1 Carrying Bag Cat 2133 76 5 10 ft 3 m Black Leads with Alligator...

Страница 5: ...ortant information to acknowledge SD card This product has been declared recyclable following an analysis of the life cycle in accordance with standard ISO 14040 This product complies with the Low Vol...

Страница 6: ...instrument s specifications for voltage or category Do not use the instrument if it seems to be damaged incomplete or improperly closed Do not use the instrument without its battery Before each use c...

Страница 7: ...he power cord into an outlet 4 Open the elastomer cover that protects the power socket 5 Connect the power supply s 4 point connector to the instrument The ON OFF button will blink while charging and...

Страница 8: ...nergy mode Recording Modes Trend mode Transient mode Inrush Current mode Alarm mode Monitoring mode N L1 L2 L3 N L1 L2 L3 Measurement terminals Touch screen Function buttons Yellow buttons Configurati...

Страница 9: ...tors for voltage terminals The same color as the terminal Strap attachment point Theft proofing device for securing the instrument with a Kensington lock RJ45 connector for Ethernet connection USB typ...

Страница 10: ...ent sensors all 3 sensors 3A or only 2 A1 and A2 or A2 and A3 or A3 and A1 For three phase 4 and 5 wire networks you must indicate the connected voltages all 3 voltages 3V or only 2 V1 and V2 or V2 an...

Страница 11: ...curves to adjust the display s brightness and auto off to manage the contents of the external memory to configure the network communication of the instrument to configure the Ethernet link to configur...

Страница 12: ...fy the voltage ratios the current sensor ratios and the range of the sensor to choose the ratios of phase to neutral voltages with neutral to choose the ratios of phase to phase voltages without neutr...

Страница 13: ...ts except harmonics powers and energies Harmonic Mode Press the button to enter Harmonics mode The Harmonics mode displays a bargraph that represents the harmonics of the voltage current and mains sig...

Страница 14: ...ergy Mode Press the button to enter Energy mode The Energy mode is used to meter generated and consumed energy over a period and indicate the corresponding price Recording Modes Trend Mode Press the b...

Страница 15: ...aves which are very high voltages for a very short time Inrush Current Mode Press the button and select a recording from the list to view the associated Inrush Current measurements The Inrush Current...

Страница 16: ...to check the voltage s conformity for a specified duration Use the application software to configure the Monitoring mode The Monitoring mode monitors electrical networks per standard EN 50160 In this...

Страница 17: ...n functions and symbols Application Software The application software is available on the provided USB drive or on our website at www aemc com dataview software Go to the Support tab and search for th...

Страница 18: ...ibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 23...

Страница 19: ...you must do to return an Instrument for Warranty Repair First send an email to repair aemc com requesting a Customer Service Authorization Number CSA from our Service Department You will be provided...

Страница 20: ...AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 800 343 1391 Fax 603 742 2346 www aemc com 11 22 99 MAN 100564 v0 Chauvin Arnoux Inc d b a AEMC Instruments All Rights Reserved...