POWER CLAMP-ON METER

User Manual 

EN G L I S H  

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 2139.50

Страница 1: ...405 POWER CLAMP ON METER User Manual ENGLISH www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...2 TURNING THE CLAMP ON METER ON 20 3 3 TURNING THE CLAMP ON METER OFF 20 3 4 CONFIGURATION 20 3 4 1 Configuring the Maximum Resistance for Continuity 21 3 4 2 Auto Power OFF 21 3 4 3 Configuring the T...

Страница 3: ...ent 39 4 2 10 Diode test 39 4 2 11 Active DC Power Measurements 40 4 2 12 Active AC Power Measurements 40 4 2 13 Active AC DC Power Measurements 41 4 2 14 Measurement of Apparent AC Power 42 4 2 15 Me...

Страница 4: ...s marked Risk of electric shock The voltage at the parts marked with this symbol may be dangerous Refers to a type A current sensor This symbol signifies that application around and removal from HAZAR...

Страница 5: ...ation on the leads housing and accessories Any element of which the insulation is deteriorated even partially must be set aside for repair or scrapped Use leads and accessories rated for voltages and...

Страница 6: ...If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to s...

Страница 7: ...asures harmonic distortion THD Continuity test with buzzer Resistance measurement Diode test Power measurements W VA var and PF Phase order indication Item Designation See 1 Jaws with centering marks...

Страница 8: ...ion See 1 OFF mode Turns the clamp on meter off 3 3 2 AC DC AC DC voltage measurement V 3 5 3 Continuity test Resistance measurement Diode test 3 6 3 7 3 8 4 AC DC AC DC current measurement A 3 9 5 Po...

Страница 9: ...ions AC DC AC DC Selection of single phase or 3 phase measurement 2 2 3 Enables disables display backlighting 2 3 4 Enables disables the MAX MIN PEAK mode Enables disables the True InRush mode in curr...

Страница 10: ...mode display 1 1 7 Low battery indication 5 3 1 3 1 Display Symbols Symbol Designation AC Alternating current or voltage DC Direct current or voltage AC DC Alternating and direct current or voltage R...

Страница 11: ...distortion with respect to the true RMS value of the signal Phase order indication Lead resistance compensation Continuity test Diode test Auto Power Off disabled Low battery indicator The display of...

Страница 12: ...e terminals are used as follows 1 2 Figure 5 The Terminals Item Function 1 COM black Input Terminal Jack 2 Positive red Input Terminal Jack www GlobalTestSupply com Find Quality Products Online at sal...

Страница 13: ...es acquired specific to each function V A W according to the specific modes previously activated MAX MIN The present display is then maintained while the detection and acquisition of new values contin...

Страница 14: ...Depending on your choice the screen displays AC DC or AC DC Cycles through the continuity and diode test modes and returns to the continuity test Resets the measurement process for the phase order ind...

Страница 15: ...exiting from the mode the values already detected are not erased NOTE The MAX MIN PEAK or PEAK symbols are all displayed but only the symbol of the measurement selected blinks Example If MIN has been...

Страница 16: ...Rush mode Inrh is displayed for 3s the backlighting blinks The triggering threshold is displayed for 5s the backlighting is steady is displayed and the A symbol flashes backlighting turns off After de...

Страница 17: ...e power W long Enters or exits from the level of harmonics THD calculation and display mode then short Selects THDf THDr or the frequency of the fundamental 2 5 2 The Hz Function Activation of the HOL...

Страница 18: ...e The Ref symbol is displayed Displays the differential value current value reference The REL symbol is displayed Displays the relative value in current value reference The REL and symbols are display...

Страница 19: ...e switch to the desired function The display lights all symbols for a few seconds see 1 3 then the screen of the function chosen is displayed The clamp on meter is now ready to make measurements 3 3 T...

Страница 20: ...ng The detection threshold chosen is stored and a double beep is emitted 3 4 2 Auto Power Off The Auto Power Off feature is enabled by default To disable it perform the following 1 In the OFF position...

Страница 21: ...ll screen display ends and a beep is emitted The rSt symbol is displayed 2 After 2 s the clamp on meter emits a double beep then all of the digital symbols of the screen are displayed until the yellow...

Страница 22: ...yed 2 Connect the black lead to the COM terminal and the red lead to the terminal 3 Connect the test probes or the alligator clips to the circuit or component to be measured An audible signal is emitt...

Страница 23: ...lue is stored only if it is 2 Above 2 the value displayed blinks and is not stored 3 7 RESISTANCE MEASUREMENT Warning Before making a resistance measurement make sure that the circuit is off and all c...

Страница 24: ...n meter see the diagram below should point in the presumed direction of current flow from the generator to the load Make sure that the jaws have closed correctly after clamping around the conductor NO...

Страница 25: ...button until the device emits a double beep and displays a value near 0 The correction value is stored until the clamp is powered down NOTE The correction is effected only if the value displayed is 10...

Страница 26: ...e clamp then awaits detection of the True InRush current is displayed and the A symbol flashes 3 After detection and acquisition for 100 ms the RMS value of the True InRush current is displayed Pressi...

Страница 27: ...by pressing the button until the desired choice is reached 2 The device automatically displays AC DC To select AC DC or AC DC press the yellow button until the desired choice is reached 3 Connect the...

Страница 28: ...nected and the black lead is connected then the clamp is on the conductor To the L1 phase to the L2 phase of the L3 phase To the L2 phase to the L3 phase of the L1 phase To the L3 phase to the L1 phas...

Страница 29: ...Err Hz or ErrV message The symbol flashes then the rdy message is displayed on the screen Repeat the procedure from Step 4 Step 2 Determining the Measurement Period 1 Within the next 10 seconds apply...

Страница 30: ...the yellow button until the desired choice is reached 3 Connect the black lead to the COM terminal and the red lead to the terminal 4 Connect the test probes or the alligator clips to the circuit to...

Страница 31: ...ntil the desired choice is reached 3 Connect the black lead to the COM terminal and the red lead to the terminal 4 Place the test probes or the alligator clips of the black lead on the neutral N and t...

Страница 32: ...r press the button again The THDr symbol is displayed To select the frequency of the fundamental press the button again The Hz symbol is displayed 2 Connect the black lead to the COM terminal and the...

Страница 33: ...34 The measurement is displayed on screen www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 34: ...is expressed in x of the reading R y counts ct 4 2 1 DC Voltage Measurement Measurement Range 0 00 to 99 99V 100 0 to 999 9V 1000V 1 Specified Measurement Range 0 to 100 of the measurement range Accur...

Страница 35: ...fications in MAX MIN mode from 10Hz to 1kHz and from 0 30V in AC Accuracy add 1 R to the values of the table above Capture of the extreme approximately 100ms 4 2 3 AC DC Voltage Measurement Measuremen...

Страница 36: ...on 0 01A 0 1A 1A Note 1 The display indicates OL above 3000A and OL below 3000A in REL mode The and signs are displayed Note 2 The residual current at zero depends on the remanence It can be corrected...

Страница 37: ...on the remanence This can be corrected by the DC zero function of the HOLD button In AC 150mA Specific Specifications in MAX MIN mode from 10Hz to 1kHz and from 0 30A in AC Accuracy add 1 5 L 0 5A to...

Страница 38: ...Current 550 A 100 A 10 A Note 1 Above the maximum display value the display unit indicates OL The and signs are not managed Specific Specifications in MAX MIN mode Accuracy add 1 R to the values of th...

Страница 39: ...ll be 0 1A 10A or 1 4 2 12 Active AC Power Measurements Measurement Range 2 4 5 to 9999W 10 00 to 99 99kW 100 0 to 999 9kW 1000kW 1 Specified Measurement Range 1 to 100 of the measurement range 0 to 1...

Страница 40: ...2 4 5 to 9999W 10 00 to 99 99kW 100 0 to 999 9kW 1000 to 1500kW 1 Specified Measurement Range 1 to 100 of the measurement range 0 to 100 of the measurement range Accuracy 3 1000A 2 R 10cts 1000 to 150...

Страница 41: ...ent range 0 to 100 of the measurement range Accuracy 3 1000A 2 R 10cts 1000 to 1500A 2 5 R 10cts 1000A 2 R 3cts 1000 to 1500A 2 5 R 3cts Resolution 1VA 10VA 100VA 1000VA Note 1 Display of OL above 150...

Страница 42: ...for 30 THD 40 4 2 17 Measurement of Reactive AC DC Power Measurement Range 2 4 5 to 9999 var 10 00 to 99 99 kvar 100 0 to 999 9 kvar 1000 to 1500 kvar 1 Specified Measurement Range 1 to 100 of the mea...

Страница 43: ...12 Quadrant 1 Power factor PF sign inductive system Cos sign Quadrant 2 Power factor PF sign inductive system Cos sign Quadrant 3 Power factor PF sign inductive system Cos sign Quadrant 4 Power facto...

Страница 44: ...Measurement Range 0 to 100 of the measurement range Accuracy 5 R 2cts in voltage 5 R 5cts in current Resolution 0 1 4 2 21 Specifications in THDf Measurement Range 0 0 to 1000 Specified Measurement R...

Страница 45: ...0 4 3 ENVIRONMENTAL CONDITIONS Conditions Operating Storage Temperature 4 to 131 F 20 to 55 C 40 to 158 F 40 to 70 C Relative humidity RH 90 up to 131 F 55 C 90 up to 158 F 70 C 4 4 MECHANICAL SPECIFI...

Страница 46: ...liant with standards IEC 61010 1 IEC 61010 2 30 and IEC 61010 2 32 1000V CAT IV Electromagnetic compatibility Compliant with standard EN 61326 1 Classification residential environment Mechanical stren...

Страница 47: ...t 4 R 1 ct 1 R 1 ct 9 R 1 ct 1 R 1 ct 5 R 1 ct Position of the conductor in the jaws f 400 Hz Any position on the internal perimeter of the jaws A W 2 R 8 R 4 R 1 ct Full scale Adjacent conductor carr...

Страница 48: ...h or forced air Dry completely before putting back into use 5 3 REPLACEMENT OF THE BATTERIES The symbol indicates that the batteries are low When this symbol appears on the display unit the batteries...

Страница 49: ...g container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T includes calibration certificate plus recorded calibr...

Страница 50: ...nstrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material 9 WARRANTY R...