ELECTRICAL SPECIFICATIONS

Nominal Range:

5A, 100A

Measurement Range:

5A: 0.005 to 6A

100A: 0.1 to 120A

 

Transformation Ratio:

Voltage output

 

Output Signal:

5A: 200mV/A 

100A: 10mV/A

 

Accuracy and Phase Shift*: 

5A Range - Accuracy

Ip 

0.005A

0.05A

0.5A

5A

Vs % 

1.5 % 

+0.02mV

1.5% 

1%

1%

Phase 

6.5 ° 

5 ° 

4.5 ° 

4 ° 

100A Range - Accuracy 

Ip 

0.1A

1A

10A 

100A

Vs % 

1% 

+0.02mV

1%

1%

1%

Phase 

3.2 ° 

2.2°

2.2 ° 

2.2 ° 

*Reference conditions: 18°C to 28°C, 20 to 75% RH,
external magnetic field <40 A/m, 48 to 65Hz sine wave, 
distortion factor less than 1%, no DC component, no
external current carrying conductor, test sample
centered. Load impedance > 1M

Frequency Range:

40 to 10kHz

Limit Operating Conditions:

200A MAX to 1kHz; Derating above 1kHz: 
200A x (1*F), F in kHz

Working Voltage:

600Vrms 

Common Mode Voltage:

600Vrms

 

Influence of Adjacent Conductor: 

< 15mA/A at 50Hz

Influence of DC on AC signal: 
5A Range:

DC Current < 1A, < 3%

100A Range:

DC Current < 10A, < 10% 

Influence of Conductor Position in Jaw: 

0.5% of mV output @ 50/60Hz

Influence of Frequency:
5A Range:

40Hz to 1kHz: <0.7% of mV output
1kHz to 3kHz: <2%% of mV output

150A Range:

40Hz to 1kHz: <0.7% of mV output
1kHz to 3kHz: <0.7% of mV output 

Influence of Temperature: 

 200 ppm/°K, or 0.2% of mV output

per 10°K 

Influence of Humidity (10 to 90% RH): 

 0.2% of mV output per 10°K @ 18° to 28°C 

MECHANICAL SPECIFICATIONS

Operating Temperature:

14° to 131°F (-10° to +55°C)

Storage Temperature:

-40° to 158°F (-40° to +70°C)

Operating Relative Humidity:

10° to 35°C 85% RH  
(without roll-off above 35°C)

Maximum Cable Diameter: 

One Ø 0.78" (20mm), bus bar 20 x 5 mm 

Case Protection:

IP 40 (IEC 529)

Drop Test: 

Test per IEC 68-2-32:
1.0 m drop on 38mm of Oak on concrete 
Test per IEC 68-2-27

Vibration:

Test per IEC 68-2-6

Dimensions:

5.47 x 2.00 x 1.18"  
(139 x 51 x 30mm) 

Weight:

180g (6.5oz)

Polycarbonate Material:

Jaws:  Polycarbonate with 10% fiberglass 
charge, Red UL 94 V0 
Case: Polycarbonate 920A Gray

Opening Operations - Life:

 > 50,000

 

Output:

10 ft (3m) insulated lead with BNC connector 

SAFETY SPECIFICATIONS 

Electrical:

Double insulation or reinforced insulation 
between the primary or secondary and the 
outer case of the handle conforms to IEC 
1010-2-32.

Common Mode Voltage:

600V CAT III, Pollution Degree 2 

Electromagnetic Compatibility:

Emissivity: EN61326-1 Class B
Electrostatic discharge IEC 1000-4-2
Radiated field IEC 1000-4-3
Fast transients IEC 1000-4-4
Magnetic field at 50/60Hz IEC 1000-4-8

ORDERING INFORMATION

AC Current Probe MN379T .....Cat #2153.02 

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Содержание MN379T

Страница 1: ...ranted to the owner for a period of two years from the date of original purchase against defects in manufacture This limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and product registration is...

Страница 2: ...ce of Temperature 200 ppm K or 0 2 of mV output per 10 K Influence of Humidity 10 to 90 RH 0 2 of mV output per 10 K 18 to 28 C MECHANICAL SPECIFICATIONS Operating Temperature 14 to 131 F 10 to 55 C Storage Temperature 40 to 158 F 40 to 70 C Operating Relative Humidity 10 to 35 C 85 RH without roll off above 35 C Maximum Cable Diameter One Ø 0 78 20mm bus bar 20 x 5 mm Case Protection IP 40 IEC 52...

Страница 3: ...ce of Temperature 200 ppm K or 0 2 of mV output per 10 K Influence of Humidity 10 to 90 RH 0 2 of mV output per 10 K 18 to 28 C MECHANICAL SPECIFICATIONS Operating Temperature 14 to 131 F 10 to 55 C Storage Temperature 40 to 158 F 40 to 70 C Operating Relative Humidity 10 to 35 C 85 RH without roll off above 35 C Maximum Cable Diameter One Ø 0 78 20mm bus bar 20 x 5 mm Case Protection IP 40 IEC 52...

Страница 4: ...ranted to the owner for a period of two years from the date of original purchase against defects in manufacture This limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and product registration is...

Отзывы: