AEMC instruments AmpFlex 193-24-BK Скачать руководство пользователя страница 23

Current Probes & Sensors for Power Quality Meters and Power Energy Loggers 

23

5.5.1  Warranty Repairs

What you must do to return an Instrument for Warranty Repair:

First, send an email to 

[email protected]

 requesting a Customer Service Autho-

rization Number (CSA#) from our Service Department. You will be provided a CSA 

Form and other required paperwork along with the next steps to complete the 

request. Then return the instrument along with the signed CSA Form. Please write 

the CSA# on the outside of the shipping container. Return the instrument, postage 

or shipment pre-paid to:

 

Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments 

 

15 Faraday Drive, Dover, NH 03820 USA 

 

Phone: (800) 945-2362 (Ext. 360) / (603) 749-6434 (Ext. 360) 

 

Fax:  (603) 742-2346 

 E-mail: 

[email protected]

 

C

aution: To protect yourself against in-transit loss, we recommend 

that you insure your returned material.

NOTE: You must obtain a CSA# before returning any instrument

.

Содержание AmpFlex 193-24-BK

Страница 1: ...PROBES SENSORS For Power Quality Meters Power Energy Loggers 193 24 BK 193 36 BK 196A 24 BK MA193 10 BK MA193 14 BK MA194 24 BK MN93 BK MN193 BK MR193 BK SL261 SR193 BK User Manual ENGLISH WITH AEMC INSTRUMENTS ...

Страница 2: ... 800 945 2362 or 603 749 6434 Fax 603 742 2346 This documentation is provided as is without warranty of any kind express implied or otherwise Chauvin Arnoux Inc has made every reasonable effort to ensure that this documentation is accurate but does not warrant the accuracy or completeness of the text graphics or other information contained in this documentation Chauvin Arnoux Inc shall not be liab...

Страница 3: ...us voltages Type B current sensor as per IEC 61010 2 032 Signifies that the instrument is protected by double or reinforced insulation Battery Indicates important information to acknowledge This product complies with the Low Voltage Electromagnetic Compatibility European directives 73 23 CEE 89 336 CEE In the European Union this product is subject to a separate collection system for recycling elec...

Страница 4: ...fied Comply with the conditions of use e g temperature humidity altitude degree of pollution location Do not use the current probe if its housing is open deteriorated or incorrectly reassembled Before each use check the integrity of the insulation of the unit jaws clamps housing and leads Do not subject the current probe to water or other liquids Keep the jaw contacts of the clamp absolutely clean...

Страница 5: ... MN193 BK 9 2 1 5 AC Current Probe Model MR193 BK 10 2 1 6 AC Current Probe Model SL261 11 2 1 7 AC Current Probe Model SR193 BK 12 3 OPERATION 13 4 SPECIFICATIONS 15 4 1 Electrical 15 4 2 Environmental 16 4 3 Mechanical 16 4 4 Safety 17 4 5 Conformity To International Standards 17 4 6 Electromagnetic Compatibility 17 5 MAINTENANCE 18 5 1 Cleaning 18 5 2 Battery Replacement 18 5 2 1 Model MR193 BK...

Страница 6: ...ent probes in this manual are compatible only with AEMC Instruments Power Analyzers see 4 for meter compatibility AmpFlex Sensor 24 Model 193 24 BK Cat 2140 34 AmpFlex Sensor 36 Model 193 36 BK Cat 2140 35 AmpFlex Sensor 24 Model 196A 24 BK Cat 2140 75 MiniFlex Sensor 10 Model MA193 10 BK Cat 2140 48 MiniFlex Sensor 14 Model MA193 14 BK Cat 2140 50 MiniFlex Sensor 24 Model MA194 24 BK Cat 2140 80 ...

Страница 7: ...ergy Loggers 7 2 PRODUCT FEATURES 2 1 Control Features AmpFlex Models 193 24 BK 193 36 BK 196A 24 BK 2 3 4 1 1 Flexible sensor 2 Sensor opening connector 3 Shielded lead 4 Custom 4 pin input connector available standard or IP 67 compliant depending on instrument ...

Страница 8: ...8 Current Probes Sensors for Power Quality Meters and Power Energy Loggers 2 1 1 MiniFlex Model MA193 BK 2 3 4 1 1 Flexible sensor 2 Sensor opening device 3 Shielded lead 4 Custom 4 pin input connector ...

Страница 9: ...Current Probes Sensors for Power Quality Meters and Power Energy Loggers 9 2 1 2 MiniFlex Model MA194 BK 4 2 3 1 1 Flexible sensor 2 Sensor opening device 3 Shielded lead 4 Custom 4 pin input connector ...

Страница 10: ...2 1 3 AC DC Current Probe Model J93 BK 1 2 4 5 6 3 5000A 500A ZERO Stop Test MARCHE SORTIE ZERO ON OFF 300VCA TIV 600VCA TIII 1 Jaws 2 Custom 4 pin input connector 3 Safety guard 4 Zero adjustment knob 5 Power ON Low battery indicator 6 Three position switch ON OFF battery test ...

Страница 11: ...nd Power Energy Loggers 11 2 1 4 AC Current Probe Models MN93 BK MN193 BK 200V CAT IV 600V CAT III 200A 5 4 2 3 6 1 1 Jaws 2 Protective guard 3 Two position range switch MN193 BK only 4 Jaw opening lever 5 Shielded lead 6 Custom 4 pin input connector ...

Страница 12: ...wer Quality Meters and Power Energy Loggers 2 1 5 AC Current Probe Model MR193 BK 5 2 4 3 7 6 1 1 Jaws 2 Protective guard 3 Jaw opening lever 4 Two position range switch 5 Shielded lead 6 Zero adjustment 7 Custom 4 pin input connector ...

Страница 13: ...ality Meters and Power Energy Loggers 13 2 1 6 AC Current Probe Model SL261 2 3 5 6 4 1 1 Jaws 2 Zero adjust knob 3 Range selection switch 4 Battery compartment screw 5 Battery compartment cover 6 BNC Adapter sold separately Cat 2140 40 ...

Страница 14: ...ent Probes Sensors for Power Quality Meters and Power Energy Loggers 2 1 7 AC Current Probe Model SR193 BK 4 2 3 5 1 1 Jaws 2 Protective guard 3 Jaw opening lever 4 Shielded lead 5 Custom 4 pin input connector ...

Страница 15: ...ed ID markers to associate a color for each current input to match the phase identifiers on the measured system NOTE Always connect the probes or sensors with the indicating arrows pointing toward the load For Example Only instrument s will vary Connect the current probe or sensor to the current terminals of the instrument For MR193 BK and SL261 Probes MR193 BK Set the switch to 1 mV A the ON indi...

Страница 16: ...nd MiniFlex Sensors AmpFlex Press simultaneously on both sides of the opening connector MiniFlex Press the opening device to open the flexible sensor Clamp the sensor around the conductor to be tested For best results center the conductor in the jaws of the clamp Close the sensor by pushing the moving part into the connector until it clicks NOTE For details of the measurement configuration and tec...

Страница 17: ...m 200 mA to 3000 A 10 000 A peak All PowerPads and PEL 100 Series MiniFlex MA194 BK 1 24 in 606 mm 100 mA to 3000 A 10 000 A peak All PowerPads and PEL 100 Series J93 BK 50 to 3500 50 to 5000 DC only 8333 8336 8435 8436 and PEL 100 Series MN93 BK 2 to 240 AAC I 200 A not permanent All PowerPads and PEL 100 Series MN193 BK 5 A 0 005 to 6 AAC 100 A 0 1 to 120 AAC All PowerPads and PEL 100 Series MR1...

Страница 18: ... BK 10 in 250 mm 10 ft 3 m 2 75 in 70 mm 4 0 x 2 5 x 1 1 in 103 x 64 x 28 mm 1 94 oz 55 g MiniFlex MA193 14 BK 14 in 350 mm 10 ft 3 m 3 94 in 100 mm 4 0 x 2 5 x 1 1 in 103 x 64 x 28 mm 2 11 oz 60 g MiniFlex MA194 24 BK 24 in 606 mm 10 ft 3 m 7 64 in 190 mm 4 0 x 2 5 x 1 1 in 103 x 64 x 28 mm 2 11 oz 60 g J93 BK 10 ft 3 m 2 84 in 72 mm 13 23 x 5 00 x 1 65 in 336 x 127 x 42 mm 3 75 lbs 1 7 kg MN93 B...

Страница 19: ...96A BK 1000 V CAT IV MiniFlex BK 1000 V CAT III 600 V CAT IV J93 BK 600 V CAT III 300 V CAT IV MN93 MN193 BK MN194 BK 600 V CAT III 300 V CAT IV MR193 BK 600 V CAT III 300 V CAT IV SL261 600 V CAT III SR193 BK 1000 V CAT III 600 V CAT IV 4 5 Conformity To International Standards The instruments are compliant with IEC 61010 2 032 The equipment is protected by double or reinforced insulation Type of...

Страница 20: ...ter directly on the instrument 5 2 Battery Replacement 5 2 1 Model MR193 BK Disconnect the MR193 BK completely and turn the rotary switch to OFF Use a screwdriver to unscrew the screws and remove the battery compartment cover on the backside of the unit Withdraw the battery from its compartment Disconnect the old battery without pulling on the wires and replace with a new one observing the polarit...

Страница 21: ...es For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA Send an email to repair aemc com requesting a CSA you will be provided a CSA Form and other required paperwork along with the next steps to complete the request Then return the instrument along with the signed CSA Form This will ensure that when your instrument arrives it wi...

Страница 22: ...chase against defects in manufacture This limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and product registration is available on our web site at www aemc com warranty html Please print the o...

Страница 23: ...ng with the next steps to complete the request Then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 E mail repair aemc com Caution To pr...

Страница 24: ...AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 800 343 1391 Fax 603 742 2346 www aemc com 02 23 99 MAN 100391 v12 Chauvin Arnoux Inc d b a AEMC Instruments All Rights Reserved ...

Отзывы: