AC/DC Current Probe Model MR6292
9
3. SPECIFICATIONS
3.1 ELECTRICAL
Measurement Range:
1 to 50 A
dc
Accuracy:
1 to 50 A
dc
: 1.5 % reading ± 0.2 A
Output Signal:
10 mV/A
dc
Load Impedance:
> 100 k
Ω
/ 100 pF
Insertion Impedance:
0.39 m
Ω
@ 50 Hz, 58 m
Ω
@1000 Hz
Working Voltage:
600 Vrms
Common Mode Voltage:
600 Vrms
Influence of Adjacent Conductor:
< 10m A/A at 50 Hz at 23 mm from the probe
Influence of Conductor in Jaw Opening:
0.5 % reading
Power Source:
Powered by Micro-Ohmmeter Model 6292
3.2 MECHANICAL
Jaw Opening:
1.2 in (31 mm)
Maximum Cable Diameter:
One 1.18 in (30 mm) or two 0.95 in (24 mm) or
two bus bars (1.2 x 0.4) in (31.5 x 10) mm
Dimensions:
(8.8 x 3.82 x 1.73) in (224 x 97 x 44) mm
Weight:
15 oz (440 g)
Output:
4-conductor shielded cable with 5-pin XLR connector
Zero Adjustment:
Automatic zero by Model 6292
Case Protection:
IP30 per IEC 529
Drop Test:
1.0 m on 38 mm of oak on concrete; test according to EN 61010
Mechanical Shock:
100 G, test per IEC 68-2-27
Vibration:
Test per IEC 68-2-6
Handle:
UL 94 V0
Jaws:
UL 94 V0