background image

Operating Instructions 

Combined Wind Sensor ARCO SDI-12

(14582) ARCO SDI-12

Operating Instructions

Subject to change without notice. 

Technical data 

ARCO SDI-12

 

Id-No. 00.14582.070470

Range   

Temperatures -40...+70 °C  

 

of application: 

Wind speed 0...55 m/s  

 

 

 

0...100 % r. h.

Protocol: 

SDI-12

Supply voltage: 

Sensor 9...15 VDC · 4 mA at 12 VDC

Housing: 

Seawater resistant aluminium    

 

 

specially coated

 

 

IP 65 in vertical position of use

Dimensions: 

See dimensioned drawing

Weight:  

Approx. 1.7 kg

Parameter wind direction

Measuring range: 

0...360°

Accuracy: 

± 1 %

Resolution: 

< 1° 

Starting value: 

0.3 m/s

Damping ratio: 

0.5...0.6

Parameter wind speed

Measuring range: 

0.3...55 m/s

Accuracy: 

± 2 % FS at 0.3...55 m/s

Resolution: 

< 0.1 m/s

Starting value: 

0.3 m/s

Distance constant:   4 m

Accessories:

 

(

please order separately) 

Sensor connection cable with plug connector M12, 4-pin

Length:   

12 m

Id-No:   

32.14567.060000

Sensor connection cable with plug connector M12, 4-pin

Length:   

15 m

Id-No:   

32.14567.060010

(Other lengths available on request.)

Options:
(9340)  Visualisation and evaluation software

 

MeteoWare-CS-3 Basic

 

Id-No. 36.09340.000000

Standards

• 

EMC/EMI: EN 60945

• 

Low voltage guideline 73/23/EWG and VDE 0100

• 

WMO No. 8

• 

VDI 3786 part 2

• 

SDI12, 1.4, 2017 

9 Warranty

Please note the loss that unauthorised manipulation 

of the system shall result in the loss of warranty and 

non-liability. Changes to system components require 

express written permission from LAMBRECHT meteo 

GmbH. These activities must be performed by a qualified 

technician.

The warranty does not cover:

 

1.  Mechanical damage caused by external impacts (e. g. 

icefall, rockfall, vandalism).

2.  Impacts  or  damage  caused  by  over-voltage  or 

electromagnetic fields which are beyond the standards 

and specifications of the device. 

3.  Damage caused by improper handling, e. g. by using 

the wrong tools, incorrect installation, incorrect electrical 

installation (incorrect polarity) etc.

4.  Damage caused by using the device outside the specified 

operation conditions.

10 Disposal

LAMBRECHT meteo GmbH is listed and registered at the 

Stiftung Elektro-Altgeräte Register ear under:

WEEE-Reg.-No. DE 45445814

In the category of monitoring and control instruments, device 

type: "Monitoring and control instruments for exclusively com-

mercial use".

Within the EU

The device has to be disposed according 

to the European Directives 2002/96/EC and 

2003/108/EC (Waste Electrical and Elec-

tronic Equipment). Do not dispose the old 

device in the household waste! For an 

environmentally friendly recycling and dis-

posal of your old device, contact a certified 

disposal company for electronic waste.

Outside the EU

Please follow the regulations in your country regarding the 

appropriate disposal of waste electronic equipment.

14

LAMBRECHT meteo GmbH 

 Tel 

+49-(0)551-4958-0

Friedländer Weg 65-67 

 Fax 

+49-(0)551-4958-312

37085 Göttingen 

 

 E-Mail  [email protected]

Germany 

 

 Internet  www.lambrecht.net

14582_ARCO_SDI-12_b-de.indd    21.22

Содержание LAMBRECHT meteo ARCO SDI-12

Страница 1: ...and special alloys Corrosion resistant surfaces for long service life Particularly low starting value 0 3 m s Measuring range from 0 3 55 m s Quick and easy installation thanks to pipe mounting and M...

Страница 2: ...2 5 Mounting the cup rotor 4 2 6 Mounting the wind vane 4 2 7 Installation procedure brief description 4 2 7 1 Mounting the sensor 4 2 7 2 Power supply and signal cables 5 2 7 3 Safety regulations 5 3...

Страница 3: ...speaking they apply only to the location where the measuring instrument is installed Therefore special attention should be paid to the choice of installation location For wind measurements according t...

Страница 4: ...50 mm and an inside diameter of at least 40 mm Before attaching the instrument with the two grub screws M8 x 12 connect the cable lead it through the pipe and align the sensor to the north For this pu...

Страница 5: ...ety regulations must be followed dur ing installation During the electrical installation work the relevant circuits must be disconnected from the power supply The housing must only be opened by author...

Страница 6: ...Operating Instructions Combined Wind Sensor ARCO SDI 12 14582 ARCO SDI 12 Operating Instructions 5 Dimensioned drawing ARCO SDI 12 6...

Страница 7: ...Operating Instructions Combined Wind Sensor ARCO SDI 12 14582 ARCO SDI 12 Operating Instructions 6 Electrical connection ARCO SDI 12 7...

Страница 8: ...CR LF aMC Start Measurement and Request CRC atttn CR LF aC Start Concurrent Measurement atttnn CR LF aCC Start Concurrent Measurement and Request CRC checksum atttnn CR LF aD0 Send Data Buffer 0 a dat...

Страница 9: ...speed 14582D Wind direction 1 1 Firmware version End of command CR LF End of answer Example Command Answer 0I 014LMGmbH1514582S1 1 CR LF 1I 114LMGmbH1514582D1 1 CR LF Change address aAb The factory se...

Страница 10: ...always responds with a000 The data is therefore immediately available This is also the reason why the ARCO SDI 12 does not send a service request and ignores measurement inter ruption commands The da...

Страница 11: ...ly with multiple sensors on the same bus The aC command requests the sensor to process the available measurement data and write them to an output string Unlike the standard sensors described in the SD...

Страница 12: ...mmand Answer 1CC 100004 CR LF Send Data aD0 The data requested by the sensor with the commands C or M can be retrieved with the command aD0 The sensor uses the corresponding signs or as field separato...

Страница 13: ...e Command Answer 0C 000004 CR LF 0D0 0 0 1 0 1 0 1 0 1 CR LF Syntax for measurements with command aCC or aMC Command Answer aD0 a values CRC CR LF a Sensor address a Sensor address D Command Send Data...

Страница 14: ...onents require express written permission from LAMBRECHT meteo GmbH These activities must be performed by a qualified technician The warranty does not cover 1 Mechanical damage caused by external impa...

Отзывы: