AEM 30-2500 Скачать руководство пользователя страница 22

 

 

 

 
 
DRILL TEMPLATE 

 

A drill template is provided to aid in determining mounting hole locations when mounting 
the AQ1 Data Logger.  Before drilling any holes, make sure the drill template is printed 
to the proper size.  The two vertical lines on the drill template are spaced one inch apart 
when the drill template is printed to the proper size.  Verify the two vertical lines are one 
inch apart on the printed drill template.  Due to variances in printers, the print size may 
need to be adjusted if the two vertical lines are not one inch apart. 
 
 

 

 
 

Figure 27.  AQ1 Data Logger Mounting Drill Template. 

AEM CHIPS

PERFORMANCE CHIPS

Содержание 30-2500

Страница 1: ...P N 30 2500 AQ1 Data Logger Instruction Manual...

Страница 2: ...nstallation 2 Using the AQ1 Data Logger 7 Connector Pinout 17 Specifications 19 Notes 19 Recommended Parts 21 Replacement Parts 21 Warranty 21 Drill Template 22 INSTALLATION MOUNTING THE AQ1 DATA LOGG...

Страница 3: ...RED SWIGN Connect to a fused 5 Amp switched 12 volt power source BLACK BATT GND Connect to a clean power ground Do not connect to a sensor ground AEMnet AEMnet is an open architecture software and har...

Страница 4: ...orresponding wires in the harness for Analog 1 4 are Yellow and are labeled INPUT 1 INPUT 2 INPUT 3 and INPUT 4 Analog Frequency 5 8 are analog inputs for that can optionally measure frequency 0 5 V o...

Страница 5: ...below shows wiring diagrams for an on off activation switch and a nitrous solenoid The corresponding wires in the harness for Digital 1 3 are Brown and are labeled SW 1 SW 2 and SW 3 SENSOR POWER The...

Страница 6: ...S connection is shown below in Figure 5 AEM recommends using one of the Garmin GPS models listed below Garmin GPS 18x PC 1 Hz model with DB9 connector and 12 volt power adapter Garmin GPS18x 5Hz 5 Hz...

Страница 7: ...r viewing and analysis of log files USING THE SOFTWARE Double click on the AQ1 Data Acquisition software icon and open the AQ1 Data Logger software The icon for the AQ1 Data Acquisition software is sh...

Страница 8: ...the AQ1 Data Logger software provides a quick reference to detailed information about the options and functionality for each page in the software See Figure 9 below Figure 8 AQ 1 Dropdown Menu Figure...

Страница 9: ...1 4 inputs as well as show live data for easy setup and troubleshooting Channels are enabled by the enabled check box Both calibrated and raw non calibrated live data are shown in the Live Data secti...

Страница 10: ...Figure 11 Analog 1 Configured for GM Style Water Temp Sensor Figure 12 Selecting a Sensor...

Страница 11: ...The Input Mode is user selectable from the following six options Analog Frequency Period Duty Cycle Vehicle Speed and Engine Speed Figure 13 below shows Analog Frequency 5 configured for engine speed...

Страница 12: ...e is used for calibrating the accelerometer After mounting the AQ1 Data Logger module the accelerometer must be calibrated in order to display accurate data Click on the Choose and Calibrate button in...

Страница 13: ...AQ1 Data Logger records the data When logging the data stream from an AEM EMS the input mode must be set to AEM EMS The baud rate must be set to 19200 Figure 17 below shows the AQ1 Data Logger configu...

Страница 14: ...cted to the AEMnet are automatically detected and require no configuration The AEMnet page is shown below in Figure 18 LOG NOTES User notes can be entered in the Log Notes page Notes will be saved wit...

Страница 15: ...used for converting and downloading LOG files from the SD card To convert and open a LOG file select a file and click the open button See Figure 20 below Selecting the Delete logs from AQ 1 checkbox...

Страница 16: ...ining log time are shown as well as the device serial number and firmware version The status of the AQ1 Data Logger is also shown at the bottom left corner of the screen When the AQ1 Data Logger is co...

Страница 17: ...ave a backup copy of any logger configuration files Go to AQ1 Update Firmware and the AQ 1 Bootloader pop up window will appear Click on the Open Firmware File button and follow the on screen instruct...

Страница 18: ...16V Max INPUT 7 15 Analog Frequency 8 5V 16V Max INPUT 8 16 RS 232 Tx Output NOT APPLICABLE 17 RS 232 Rx Input NOT APPLICABLE 18 RS 232 USB GND NOT APPLICABLE 19 Power Ground BATT GND 20 Sensor 5V 5 V...

Страница 19: ...te you should set for a particular channel since there is no reason to have a very high update rate for a sensor that cannot update at the same speed or faster For example a coolant temperature sensor...

Страница 20: ...capability of the SD SDHC card An error message will be displayed during LOG file conversion if data has been lost Total Data Rate This is the data rate bytes second at which data will be written to t...

Страница 21: ...terial and workmanship for a period of twelve 12 months from date of the original purchase Products that fail within this 12 month warranty period will be repaired or replaced at AEM s option when det...

Страница 22: ...size The two vertical lines on the drill template are spaced one inch apart when the drill template is printed to the proper size Verify the two vertical lines are one inch apart on the printed drill...