background image

13

2/5/2019 -  DOCUMENT NUMBER: 10-2226

© 2019 AEM Performance Electronics

30-2226 6 Channel CAN Sensor Module

AEMnet (CAN Bus) Output

WHITE WIRE =  / CANH
GREEN WIRE = AEMnet- / CANL

CAN DBC definition files are available at 
www.aemelectronics.com

Bus Termination

All AEMnet/CAN networks must be terminated to have an

equivalent of approximately 60 Ohms of resistance. 

Generally, this means a 120 Ohm resistor connected in

parallel to /AEMnet- (or CANH/CANL) at both

physical ends of the bus run.  

bit rate

500

kb/sec

format

29

bit ID

terminating resistor

None

endianness

big / Motorola

DLC

8

0x0000B600 at 100Hz

Byte

Label

Data Type

Scaling

Offset

Range

0

Analog1

16 bit unsigned

1 Ohm/bit

0

0 to 65535 Ohm

1

2

Analog2

16 bit unsigned

1 Ohm/bit

0

0 to 65535 Ohm

3

4

Analog3

16 bit unsigned

0.001 V/bit

0

0 to 65.535 V

5

6

Analog4

16 bit unsigned

0.001 V/bit

0

0 to 65.535 V

7

0x0000B601 at 50Hz

Byte

Label

Data Type

Scaling

Offset

Range

0

Tacho

16 bit unsigned

0.1 Hz/bit

0

0 to 6553.5 Hz

1

2

n/a

n/a

n/a

n/a

n/a

3

4

n/a

n/a

n/a

n/a

n/a

5

6

FuelLevel

8 bit unsigned

1 Ohm/bit

0

0 to 255 Ohm

7

Battery Voltage

8 bit unsigned

0.1 V/bit

0

0 to 25.5 V

12 Month Limited Warranty

AEM Performance Electronics w arrants to the consumer that all AEM ELECTRONICS products w ill be free from defects in material and
w orkmanship for a period of tw elve months from date of the original purchase. Products that fail w ithin this 12-month w arranty period w ill be
repaired or replaced w hen determined by AEM that the product failed due to defects in material or w orkmanship. This w arranty is limited to the
repair or replacement, at AEM’s discretion, of the AEM Electronics part. In no event shall this w arranty exceed the original purchase price of the
AEM ELECTRONICS part nor shall AEM ELECTRONICS be responsible for special, incidental or consequential damages or cost incurred due to the
failure of this product.
Warranty claims to AEM ELECTRONICS must be transportation prepaid and accompanied by dated proof of purchase. This w arranty applies only
to the original purchaser of product and is non-transferable. All implied w arranties shall be limited in duration to the said 12-month w arranty period.
Improper use or installation, accident, abuse, unauthorized repairs or alterations voids this w arranty. 
AEM ELECTRONICS disclaims any liability for consequential damages due to breach of any w ritten or implied w arranty on all products
manufactured by AEM ELECTRONICS. 
Warranty returns w ill only be accepted by AEM ELECTRONICS w hen accompanied by a valid Return Merchandise Authorization (RMA) number.
Product must be received by AEM ELECTRONICS w ithin 30 days of the date the RMA is issued. 
Please note that before AEM ELECTRONICS can issue an RMA for any electronic product, it is first necessary for the installer or end user to
contact the tech line at 1-800-423-0046 to discuss the problem. Most issues can be resolved over the phone. Under no circumstances should a
system be returned, or an RMA requested before the above process transpires. AEM ELECTRONICS w ill not be responsible for products that are
installed incorrectly, installed in a non-approved application, misused, or tampered w ith. 
Fuel Pumps installed w ith incorrect polarity (+&- w ires crossed) w ill not be w arranted. Proper fuel filtration before and after the fuel pump are
essential to fuel pump life. Any pump returned w ith contamination w ill not be w arranted. 
Any AEM ELECTRONICS product, excluding discontinued products, can be returned for repair if it is out of the w arranty period. There is a minimum
charge for inspection and diagnosis of AEM ELECTRONICS parts w hich are out of w arranty. Parts used in the repair of AEM ELECTRONICS
electronic components w ill be extra. AEM ELECTRONICS w ill provide an estimate of repairs and must receive w ritten or electronic authorization
before repairs are made to the product. 
Need additional help?  Contact the AEM Performance Electronics tech department at 1-800-423-0046 or email us at [email protected].

Содержание 30-2226

Страница 1: ...modates a wide variety of sensors and is housed in a sealed IP67 weather resistant enclosure Sturdy construction protected inputs and simple configuration make this the perfect entry point to get ever...

Страница 2: ...he shield should only be grounded drained on one end of the wiring harness CAN wiring should utilized twisted pairs 1 TPI shielding is recommended The Sensor Module s sensor ground should be at the sa...

Страница 3: ...are objects that obtain information from one or more sources or other outputs An output manipulates the obtained data according to the operation associated with the output The result can then be used...

Страница 4: ...output This should describe what the output actually generates Select the operation to be used by the output from the drop down list Select the input from the drop down list In our example below we w...

Страница 5: ...pressure sensor data scaled in units of PSI from the Analog 3 Pin 7 input of the 30 2226 CAN Sensor Module to any Gauge item in your Dash setup Modifying the tach output scalar AEM provided dash setu...

Страница 6: ...h set up Go to Setup Display CAN Receive Import CAN Select the file 30 2226 CSM6 dbc Open ONLY select the inputs being used See example below Create functions for sensors that are being used The data...

Страница 7: ...2 5 2019 DOCUMENT NUMBER 10 2226 2019 AEM Performance Electronics 30 2226 6 Channel CAN Sensor Module Create a new output channel using the new function Assign the new output to an item on the displa...

Страница 8: ...8 2 5 2019 DOCUMENT NUMBER 10 2226 2019 AEM Performance Electronics 30 2226 6 Channel CAN Sensor Module System Schematic...

Страница 9: ...Power 5V sensor reference power output Analog Inputs 1 2 These inputs have a 2200 Ohm 5V pull up resistor and are suitable for two wire thermistor temperature sensors It is not recommended to connect...

Страница 10: ...erature Most non temperature sensors require a simpler linear scaling The AEM CD series of dashes have both of these capabilities please refer to the appropriate documentation Tachometer Input This in...

Страница 11: ...4 Air Temp Sensor DTM Style Kit Analog 2200 30 2064 Exhaust Back Pressure Sensor Install Kit Analog 100 000 30 2130 7 100 PSIa or 7 Bar Stainless Sensor Kit Stainless Steel Sensor Body Analog 100 000...

Страница 12: ...te 50 Hz FAQ Troubleshooting My CAN Sensor Module doesn t seem to be outputting anything Confirm that your CAN bus is properly terminated and that all nodes are configured for the right bus speed In a...

Страница 13: ...y claims to AEM ELECTRONICS must be transportation prepaid and accompanied by dated proof of purchase This w arranty applies only to the original purchaser of product and is non transferable All impli...

Отзывы: