AEM 30-0300 Скачать руководство пользователя страница 5

5

7/12/2017 -  DOCUMENT NUMBER: 10-0300

© 2017 AEM Performance Electronics

30-0300 X-Series UEGO Gauge

Faceplate / Bezel Installation

The gauge kit is supplied assembled with a black faceplate and black bezel.  An accessory kit is available (for purchase
through AEM dealers) which includes an optional silver  bezel  and  white  faceplate.    Please  reference  the  Optional
Accessories  section  earlier  in  the  document  for  the  appropriate  part  numbers.    Contact  your  dealer  or  visit 
www.aemelectronics.com for more information.

The faceplate may be reversible, displaying alternative scalings on either side.  Reference the Operation section of this
manual for details on how to switch the display mode when reversing the faceplate.  Disassembly is required to  change
the faceplate, flip/reverse the faceplate, or change the bezel of the gauge.  The following diagram will provide familiarization
with the major components of the gauge prior to beginning the procedure.

Item

Qty

Description

1

1

Lens

2

1

Bezel

3

1

Faceplate

4

1

Diffuser

5

1

Light Guide

6

2

Button

7

2

Mounting Stud (M4 x 0.7)

8

3

Assembly Screw

9

1

Mounting Bracket

10

2

Brass Thumb Screw (M4 x 0.7)

11

1

Printed Circuit Board (PCB)

Содержание 30-0300

Страница 1: ...bus and serial data stream are also available for logging or mixture control purposes The X Series Digital Wideband technology is US Patent 9 575 030 Features X Digital Technology Free air or resistor...

Страница 2: ...and a UEGO sensor harness B the harnesses are connected to the gauge as shown below The UEGO sensor harness simply needs to be routed to the UEGO sensor whereas the Power IO harness will require furth...

Страница 3: ...ngine compartment Take care when routing sensor harness near hot exhaust components Apply strain reliefs and wire coverings as necessary Use a 5A inline fuse on the switched 12V power supply line Pin...

Страница 4: ...e ability to perform a free air calibration is provided for users that wish to do so A free air calibration can be used as a sensor ages however new sensors should use the resistor calibration for bes...

Страница 5: ...om for more information The faceplate may be reversible displaying alternative scalings on either side Reference the Operation section of this manual for details on how to switch the display mode when...

Страница 6: ...e silver bezel may be replaced for the existing bezel at this time STEP 2 Separate the PCB 11 from the remaining components STEP 3 Slide the light guide 5 upward to remove it the buttons may fall out...

Страница 7: ...slide the buttons 6 into the slots STEP 2 Stack the diffuser 4 faceplate 3 and lens 1 in order over the buttons and on to the light guide STEP 3 Reassemble the PCB and display stack with the bezel ma...

Страница 8: ...unitless ratio that is fuel agnostic In other words a lambda reading of 1 0 is stochiometric for any fuel AFR Stoichiometric AFR Lambda In general an engine will have three areas of operation idle cru...

Страница 9: ...ndle with caution UEGO sensors are very sensitive devices that must handled and installed with care Listed below are several contaminants and conditions which will shorten the life of the sensor or re...

Страница 10: ...ted signal ground then as a last course of action connect it to the power ground of the logging device Important Note If bench testing the analog output outside of a vehicle a multimeter s positive le...

Страница 11: ...erial RS 232 Output BLUE WIRE Serial Out The serial datastream is suitable for output to third party devices such as data loggers PCs or reflashed ECUs The X Series UEGO serial datastream is designed...

Страница 12: ...the gasoline stoichiometric ratio of 14 65 which might be confusing for alternative fuels Remember that AFR lambda stoichiometric ratio For support contact AEM Technical Support at 1 800 423 0046 or...

Страница 13: ...rating Temperature min 4 20 degF degC max 16V Supply 185 85 degF degC Sensor Temperature max sensor element 1706 930 degF degC Display Range min outer LED 0 55 lambda max outer LED 1 40 lambda min inn...

Отзывы: