AEM 30-0300 Скачать руководство пользователя страница 1

P/N 30-0300

X-SERIES UEGO GAUGE

Bosch LSU4.9

AEM Performance Electronics, 2205 126th Street Unit A, Hawthorne, CA 90250 - Phone: (310) 484-2322

http://www.aemelectronics.com

STOP! - READ THIS BEFORE INSTALL OR USE!

WARNING:
THIS INSTALLATION MAY REQUIRE WELDING OR INTEGRATION INTO A VEHICLE'S ELECTRICAL SYSTEM.  DAMAGE
TO SENSITIVE ELECTRONICS, FIRE, OR EXPLOSION MAY OCCUR IF PROPER PRECAUTION IS NOT TAKEN.  IF THERE
IS ANY DOUBT, 

DO NOT

 ATTEMPT THE INSTALLATION AND CONSULT A PROFESSIONAL.

NOTE

: IT IS THE RESPONSIBILITY OF THE ENGINE TUNER TO ULTIMATELY CONFIRM THE CALIBRATION USE FOR

ANY PARTICULAR ENGINE IS SAFE FOR ITS INTENDED USE.  AEM HOLDS NO RESPONSIBILITY FOR ANY ENGINE
DAMAGE THAT RESULTS FROM THE MISUSE OF THIS PRODUCT.

Instruction

Manual

The 52mm (2-1/16”) AEM X-Series Universal Exhaust Gas Oxygen (UEGO) Gauge features a four digit central readout and
sweeping 24-color-coded LED display, providing immediate reference to the engine air fuel ratio (or lambda) in real-time.
The AEM gauge is ideal for all vehicles including carbureted applications and engine dynamometers. A 0-5V analog output
is included and can be used with data loggers or aftermarket ECUs including the AEM Infinity Engine Management
System (EMS).  In addition, an AEMnet (CAN bus) and serial data stream are also available for logging or mixture control
purposes.

The X-Series Digital Wideband technology is US Patent #9,575,030.

Features

·

X-Digital Technology

·

Free air or resistor trim calibration modes

·

Fast response, 20ms typical

·

2-1/16" / 52mm outer diameter mounting

·

8.0:1 to 20.0:1 AFR / 0.55 to 2.00 Lambda

·

Configurable 3 or 4 digit precision display mode

·

Lambda, AFR, O2 % display modes with reversible
faceplate

·

Black bezel/faceplate supplied; Silver/white available
as optional purchase

·

Locking connectors

·

Supports vehicle/system voltages up to 16V

·

Supports Bosch LSU4.9 Sensor

·

0-5V Analog Output

·

AEMnet (CAN bus) Output

·

Serial RS-232 Output

KIT CONTENTS

PN

Description

10-0300

INST, X-SERIES UEGO GAUGE

35-0300

GAUGE ASSY, X-SERIES AFR GAUGE

-

RED INSULATED BUTT CONNECTORS (4)

35-4005

WELD-IN BUNG,02 SENSOR 1214 MILD STEEL

35-8618

NUT, KNURLED, M4x0.7 (2)

35-8614

BRACKET, X-SERIES GAUGE

35-3430

PWR/IO CABLE, X-SERIES GAUGE

35-3427

SENSOR CABLE, X-SERIES GAUGE LSU4.9

35-8617

RUBBER BAND, X-SERIES GAUGE

35-2004

SENSOR, WIDEBAND UEGO BOSCH LSU 4.9

*OPTIONAL* ACCESSORIES

PN

Description

30-0300-ACC

BEZEL, X-SERIES GAUGE SILVER

FACEPLATE, X-SERIES AFR WHITE

30-2355-200

NO WELD UEGO CLAMP KIT, 1.75" to 2.00"

30-2355-250

NO WELD UEGO CLAMP KIT, 2.25" to 2.50"

30-2355-300

NO WELD UEGO CLAMP KIT, 2.75" to 3.00"

30-2355-350

NO WELD UEGO CLAMP KIT, 3.25" to 3.50"

30-4008

WELD-IN FINNED BUNG, O2 LONG, STAINLESS STEEL

35-4001

BUNG PLUG,02 SENSOR

Содержание 30-0300

Страница 1: ...bus and serial data stream are also available for logging or mixture control purposes The X Series Digital Wideband technology is US Patent 9 575 030 Features X Digital Technology Free air or resistor...

Страница 2: ...and a UEGO sensor harness B the harnesses are connected to the gauge as shown below The UEGO sensor harness simply needs to be routed to the UEGO sensor whereas the Power IO harness will require furth...

Страница 3: ...ngine compartment Take care when routing sensor harness near hot exhaust components Apply strain reliefs and wire coverings as necessary Use a 5A inline fuse on the switched 12V power supply line Pin...

Страница 4: ...e ability to perform a free air calibration is provided for users that wish to do so A free air calibration can be used as a sensor ages however new sensors should use the resistor calibration for bes...

Страница 5: ...om for more information The faceplate may be reversible displaying alternative scalings on either side Reference the Operation section of this manual for details on how to switch the display mode when...

Страница 6: ...e silver bezel may be replaced for the existing bezel at this time STEP 2 Separate the PCB 11 from the remaining components STEP 3 Slide the light guide 5 upward to remove it the buttons may fall out...

Страница 7: ...slide the buttons 6 into the slots STEP 2 Stack the diffuser 4 faceplate 3 and lens 1 in order over the buttons and on to the light guide STEP 3 Reassemble the PCB and display stack with the bezel ma...

Страница 8: ...unitless ratio that is fuel agnostic In other words a lambda reading of 1 0 is stochiometric for any fuel AFR Stoichiometric AFR Lambda In general an engine will have three areas of operation idle cru...

Страница 9: ...ndle with caution UEGO sensors are very sensitive devices that must handled and installed with care Listed below are several contaminants and conditions which will shorten the life of the sensor or re...

Страница 10: ...ted signal ground then as a last course of action connect it to the power ground of the logging device Important Note If bench testing the analog output outside of a vehicle a multimeter s positive le...

Страница 11: ...erial RS 232 Output BLUE WIRE Serial Out The serial datastream is suitable for output to third party devices such as data loggers PCs or reflashed ECUs The X Series UEGO serial datastream is designed...

Страница 12: ...the gasoline stoichiometric ratio of 14 65 which might be confusing for alternative fuels Remember that AFR lambda stoichiometric ratio For support contact AEM Technical Support at 1 800 423 0046 or...

Страница 13: ...rating Temperature min 4 20 degF degC max 16V Supply 185 85 degF degC Sensor Temperature max sensor element 1706 930 degF degC Display Range min outer LED 0 55 lambda max outer LED 1 40 lambda min inn...