Battery LED
Program LED
Forced To Arm
The Audible Notifications From The Keypad
a)
b)
c)
d)
a)
b)
a)
b)
c)
OFF --- Battery normal
ON --- Battery low
Flash --- Battery under testing
Flash Alternatively with AC power LED --- System in Standby mode
ON --- System in programming mode
OFF --- System in normal operation mode
OFF --- System armed normally
ON --- System will be forced to arm if the faulty zone is not cleared
Flash --- System forced to arm with the faulty zone(s) bypassed by the system
18
HA-263D (THE DIGITAL CONTROL KEYPAD)
NOTE:
All the above LED visual indications and audible notifications from the keypad are
independent from the indications and notifications of the control panel.
NOTIFICATIONS
1 short beep
2 short beeps
5 short beeps
1 long beep
1 short beep/30 seconds
Continuous short beeps at 0.5
second interval
Beeping increases to 4
beeps/second at the last 10
seconds
1 long beep at the end of the
period
4 short beeps with 1 second
interval
!
!
!
EVENTS
Successful key entry
Successful code entry for a specific function
Unsuccessful code entry
Code entry time expired (Maximum Allowable Time:
10 seconds/digit, 60 seconds/code)
Exit delay expired, system is armed
Battery low or AC power failure
During the Exit delay, Entry delay and System Standby
period
After an alarm condition before the system is disarmed
!
!
HA-263
RINGBACK
ON OFF
11
THE PROGRAMMING JUMPERS
WARNING BEEP
ON OFF
ON
ENTRY BEEP
EXIT BEEP
ON
OFF
OFF
AUDIBLE
BEEPS
MISC.
FUNCTIONS
HANDOVER
ON OFF
4
HA-263
4) AUDIBLE BEEPS
5) HANDOVER
6) RING-BACK
There are 3 jumpers for ON-OFF selection of Entry Beep, Exit Beep and Warning Beep
independently.
--- Beeps during the entry delay period.
--- Beeps during the exit delay period.
--- The system offers two modes of warning beep
The system gives warning beeps in alarm period and it stops the beeps
when the alarm period expires if only one of the partitions is armed.
The system gives warning beeps in both alarm period and after alarm
period if both partitions are armed. The system stops the warning
beeps when one of the partitions is disarmed. It prevents noise
disturbance to the people at the other partition in house.
The after alarm warning gets the owner to pay attention on his alarm
that was triggered and the thief might still be inside the house when
he comes back.
Handover is a special function that the system offers more security to the owner.
--- With the handover function enabled, if the Lobby zone
(zone 7) is triggered first, the instant zones (except the 24 hour instant
zone) will follow the zone 7 to give entry delay with the same delay
period. The instant zones will resume to instant mode after the entry
delay expired. With this feature, the owner can set the motion sensors for
interior protection with instant zones and the main door protection with
zone 7. The system will always give instant alarm if the person (might be
an intruder) does not enter the house through the lobby zone but break
in from window.
---The system is in normal operation. All the instant
protection zones keep in their function but not follow the delay time of
zone 7.
The delay zones in the two partitions do not have handover
function.
Ring-back signals are the loud acknowledgement signal coming out from the siren to inform the
owner of the arming and disarming status of the system.
--- The system energizes the Timing Output Relay twice to
make the siren to generate two short beeps when the system is armed;
and energizes the Output Relay once to generate one short beep when
the system is disarmed.
--- The Timing Output Relay does not activate when the
system is armed or disarmed, no beep is generated as arm-disarm
acknowledgement from siren.
a) Entry Beep
b) Exit Beep
c) Warning Beep
i)
ii)
a) Handover ON
b) Handover OFF
NOTE:
a) Ring-back ON
b) Ring-back OFF