background image

NTP & Time Settings 

 

Switch

: (Default, Enable) Enable to synchronize the date & time 

 

Primary

 

Server

Select from the listed servers in the drop box. If there is an intranet NTP server, select “User 
defined” and then input the IP address of the NTP server. 

Secondary

 

Server

The device will synchronize date & time with the secondary server if the primary server is down. 
Select from the listed servers in the drop box. If there is an intranet NTP server, select “User 
defined” and then input the IP address of the NTP server. 

Location

: Select the time zone from the drop down box. 

Day

 

Light

: (Default, Off) 

Daylight saving switch; enable to configure daylight saving date and time 

Start

Select what month (MM) of the year, what week (W) of the month, what day (DD) of the week 
and what time (hh) of the day to start daylight saving. 

End

Select what month (MM) of the year, what week (W) of the month, what day (DD) of the week 
and what time (hh) of the day to start daylight saving. 

Sync

 

Time

Configure the period of time to synchronize the date and time with the NTP server. 

Содержание BY-3000-X(S)

Страница 1: ...SIP BYOD Master BY 3000 X S User Guide V 1 2...

Страница 2: ...appears to be missing or broken contact your dealer for a replacement 1 BYOD master Unit 2 Power Adaptor optional 3 Ethernet Cable 4 User Guide This document 2 Product Description The following conta...

Страница 3: ...t mDNS to find the device or you can find the BYOD master IP address from your DHCP server Open your web browser such as Internet Explorer Chrome Firefox etc and type in the web address of the BYOD ma...

Страница 4: ...n is enabled the device will try to download its configuration file from the server specified in the Server field Server The IP address information of the cfg file server for example tftp 192 168 1 54...

Страница 5: ...booting up Server IP The IP address information of the server for downloading the firmware It can be tftp IP address of tftp ftp IP address of ftp or http IP address of http Server File Path The file...

Страница 6: ...d by a text editor such as wordpad Recover System Configuration Click the Choose File to select a preconfigured back up file and then submit to load the configuration file System Authority Username Ch...

Страница 7: ...oot Click Reboot to restart the device Global SIP Settings Port Settings SIP Listen Port Default 5060 SIP Local port ranging from 10 65533 RTP Port Base Default 10000 The port of RTP starts ranging fr...

Страница 8: ...the drop box please select one for each priority RTP Packet Length Frame size for each code G711 ranges from 20ms 30ms 40ms and 50ms G723 ranges from 30ms 60ms 90ms 120ms 150ms and 180ms G729 ranges...

Страница 9: ...ds from it such as firmware updating restart reset to factory default and etc Replace Sharp Default Enable The in the sending string will be sent as 23 if it is enabled The in the sending string will...

Страница 10: ...SIP Accounts The maximum SIP accounts of the device are two To add a new SIP account click Add To delete a SIP account check the Select box and then click Delete...

Страница 11: ...Check the server IP or account credential if the Status shows registering or register fail...

Страница 12: ...se add the port to at end for example aeicommunications com 5070 or 172 8 12 11 5061 Proxy Address Outbound proxy address Voice Mail No Voice mail number of the hard key Expire Time Default 60 SIP reg...

Страница 13: ...registration registered registering or register fail AEi SIP resilience feature also known as SIP registration failed over feature With the setting shown in the follow picture it supports up to three...

Страница 14: ...tings after scan the QR code to login the room Marriott sample JSON file path http crm aeicommunications com tw 8080 Marriott01 uiconfigMarriott01 json Network Status Show the network status of the de...

Страница 15: ...econdary DNS The secondary DNS IP address Mac Address The MAC address of the device 802 1X Setting EAP Method Default Disable The EAP method PEAP or TLS Username The username of the method Password Th...

Страница 16: ...an intranet NTP server select User defined and then input the IP address of the NTP server Location Select the time zone from the drop down box Day Light Default Off Daylight saving switch enable to c...

Страница 17: ...can the following QR code to download and activate soft phone configurations QR code link http crm aeicommunications com tw 8080 qrcode htm Room number http crm aeicommunications com tw 8080 qrcode ht...

Страница 18: ...Record of Revision Date ver Description 2022 4 22 1 0 First issue 2021 11 10 1 1 Configuration update 2023 2 21 1 2 Connectivity Update...