Aegis ALF-012300A Скачать руководство пользователя страница 2

INTRODUCTION  

Thank you for purchasing an Aegis Battery product. It is a wise choice. You are  kindly advised to 
read and familiarize with the contents of this manual prior to use as failure to do so may result in 
degraded battery characteristics.  
 
The  model  you  have  purchased  is  the 

ALF-012300A  12V,  300Ah

  rated  LiFePO4  (LFP)  Battery 

featuring  enhanced  safety,  non-toxicity,  higher  performance  and  extended  service  life  as 
compared with traditional lead-type batteries including but not limited to SLA, AGL and GEL. This 
battery was assembled in our ISO 9001 Certified production facilities and as such you can expect 
performance  and  consistency  from  this  product  and  every  other  product  you  may  be  using  or 
have used.   
 

CONTENTS 

+ Aegis Energies (dba: Aegis Battery) LiFePO4 (LFP) Battery Pack (ALF-012300A) 
+ Model Compatible Charger (If an optional Charger was purchased)  
+ 1 Copy User Manual  
 
 
 
 
 
 
 
 
 
 
 
 

 SPECIFICATIONS*  

 

Battery Type 

ABS Case 

Voltage (V) 

12V 

Capacity (Ah) 

300Ah 

Energy Stored (Wh) 

3600 Watt-Hours 

Weight 

77.1 lbs. (35.0 kg)

 

Dimension (L x W x H) 

520 mm x 267 mm x 220 mm 
20.5 in. x 10.5 in. x 8.7 in.

 

Normal Charge Voltage

 

14.6V

 

Normal Charge Current 

20.0 Amps

 

Normal Battery Cutoff Voltage

 

9.2V 

 

Nominal Continuous Discharge Current

 

50.0 Amps

 

Maximum Continuous Discharge Current

 

100.0 Amps

 

Maximum Peak Pulse Discharge Current 

200.0 Amps (2

 Seconds

 

Charge Temperature 

0°C to 45°C 

Discharge Temperature 

-20°C to 60°C 

Operating/Storage Humidity 

60±25%R.H 

Automatic Battery Protection 
Module/System 

Low /Over Voltage Disconnect   
Cell Balancing

 

Short Circuit Protection 
Reverse Polarity Protection  
 

CHARGING  

PRIOR  TO  INITIAL  USE,  ENSURE  BATTERY  HAS  TAKEN  FULL  CHARGE  AND  IS  IN  A  FULLY 
CHARGED STATE. OUR BATTERIES MAY NOT BE SHIPPED FULLY CHARGED! 

 

MAKE SURE THE CHARGER’S INDICATOR LIGHT HAS  TURNED 

GREEN 

AND WAIT  FOR 30 

MIN. ELAPSE BEFORE UNPLUGGING, CHARGE TIME VARIES FROM MODEL TO MODEL! 

 

When charging your battery, please follow the provided sequence below: 
1.

 

Attach Battery Charging Connector to Charger (This will vary depending on your selected 
model and configuration of battery). 

2.

 

Attach Charger to 110VAC Outlet. 

3.

 

When Charging you should observe a 

RED

LED Indicator: this indicates that the battery is 

currently in the Constant Current (CC) charging phase. 

4.

 

Wait for a 

GREEN

LED Indicator: this indicates the battery is currently in the Constant Voltage 

(CV) charging phase. 

5.

 

Wait 30 MINUTES before unplugging the Charger from the 110VAC Outlet 

FIRST

 and then 

disconnecting the Battery from the Charger 

SECOND.

 

 

DISCHARGING (STANDARD, SERIES/PARALLEL <0.5C DISCHARGE) 

1.

 

Make sure your load accepts 

12V

 nominal voltage. 

2.

 

Ensure the connection between the battery and the load can handle the current draw. Please 
consult references for the appropriate wire type. 

3.

 

The  maximum  continuous  discharge  current  is 

100A

.  Please  make  sure  your  electrical  load 

consumes a current 

less than 100A continuous and maximum 1200 watts of power.

 

4.

 

The battery outputs steady voltage until little capacity remains, do NOT rely on voltage as an 
indicator of remaining capacity, Aegis Battery recommends the usage of an In-Line Watt Meter 
for conveyance of accurate battery discharge telemetry.  

Series: 

Each  battery  must  be  charged  separately  and  given  a  full  charge  before  connecting  in 

series. 

Parallel:

Only connect batteries  with equal state of charge in parallel. Also, measure the internal 

resistance of each battery and only use batteries with closely matched internal resistance of the 
same make, model and batch origin. It is highly recommended that resistors be used to achieve 
equal internal resistance between batteries and to add fuse(s) to the circuit for safety reasons.  

 

SAFETY GUIDELINES  

Please  adhere  to  the  following  Safety  Guidelines  in  addition  to  all  disclosed  information  when 
using your battery. Any damage  incurred as a result of a failure to adhere to the recommended 
usage  guidelines  as  collectively  disclosed  may  result  in  a  partial  or  complete  voiding  of  the 
warranty as provided upon purchase of this battery product. 

Additional Safety Guidelines are as 

follows.

 

1.

 

Do not disassemble and/or attempt self-repair. 

2.

 

Do not short circuit positive and negative terminals. 

3.

 

Do not use lead acid chargers as they will cause damage to internal hardware. 

4.

 

Do not dispose in normal refuse bin, recycle this product only at designated facilities. 

5.

 

For long term storage, fully charge the battery and then discharge to 50% of the full capacity. 

6.

 

Do not leave the battery unattended for more than 6 months or in the presence of children. It 
is recommended to charge the battery every three months if it is not used. 

7.

 

Do not use the battery in or expose the battery to extreme temperatures. 

 

 

 

 

 

 

(

*

For full specifications, please visi

www.aegisbattery.com

 

 

    SPECIFICATIONS* 

 