+ How long will my battery last?    

 

 

Several factors that affect battery life including weather, temperature, recharge cycles, depth of 
discharge (DOD), discharge current, charging current, charging method, vibration and duration of 
static use can all have dramatic effects on battery life. A properly maintained battery should last 
2000+

 

charge discharge cycles or 

5

times as long as lead-acid use in similar conditions. 

 

+ Can I use lithium ion batteries with other types of batteries? 

No. If different types of batteries are used together, or new batteries are used with old ones, the 
difference  in  characteristics  such  as  voltage,  capacity,  and/or  internal  resistance  may  cause 
uneven discharge between the batteries leading to cell damage potentially resultant in fire.  
 

+ Is it okay to use a universal lead acid charger with high enough charging current?  

Using a  lead acid  battery charger is not recommended  because they charge at a lower 2.30V to 
2.45V  per  cell  in  addition  to  charging  in  multiple  stages  with  a  final  float  charge  setting.  This  is 
distinctly different from the Li-Ion 2-Stage charge profile. Mixing of chargers between chemistries 
will result in insufficient charging and potential damage to the battery.  
 

+ Can I connect two of the same Li-ion batteries together for more voltage/ capacity?  

Linking our Li-ion batteries in series or parallel connection is normally NOT RECOMMENDED and 
may  exceed  factory  recommended  usage  parameters.  It  is  recommended  to  purchase  a  single 
battery  with  the  requisite  capacity  and  discharge  characteristics.  Our  Battery  Management 
System (BMS) is designed for operations within a singular battery unit and we cannot guarantee 
operability  of  multiple  batteries  connected  together  regardless  of  configuration.  If,  however, 
multiple  batteries  are  required,  please  ensure  1)  the  built-in  BMS  can  support  the  operation  in 
parallel or series; 2) the batteries are of the same maker/model and from the same batch 3) peak 
discharge is at <1.0C.  
 

+ My battery will not be charged/discharged?  

There are multiple reasons including but not limited to 1) charger failure, 2) external damage to 
battery has compromised either the cell pack or BMS, 3) battery voltage has fallen to zero in one 
or  more  cells,  4)  there  is  a  connection  error  within  the  pack,  5)  a  malfunction(s)  has  occurred 
within the BMS component(s) or in extreme cases, and 6) extreme high/low temperatures may be 
inhibiting charging efficiency of the cell pack itself.  
 

+ Can I jump start a dead lithium ion battery?   

It  is  not  recommended.  Li-ion  batteries  enter  an  elevated  sensitivity  state  when  empty  and  the 
introduction of unmodulated amperage in this state will damage the cell. We highly recommend 
using our chargers to recharge a fully discharged Li-ion battery as our chargers have the sensing 
circuitry required to modulate charge current to optimally recondition fully discharged batteries.   

CONTACT 

Aegis Energies, INC. (dba: Aegis Batteries)

   

P:

 

+1 (949)-469-1776 

985 East Orangefair Ln.   

 

 

E:

 

[email protected]  

Anaheim, CA 92801 

 

 

 

W: 

www.aegisbattery.com 

WARRANTY

 

NMC 5-Year and LiFEPO4 10-Year, repairs and/or exchanges may be accepted within 2 Years of purchase and 
are subject to 30-day money back guarantee for any initial quality issues originating from Aegis Battery, issues 
resultant from negligent and/or abusive use not inclusive. Returns are subject to a 10% Restock Fee + Shipping 
Cost Charge. Exchanges are subject to a Shipping Cost Charge as determined by location and level of service.    

 
 
 

 
 

 
 
 
 

 

 
 

 

 

 
 
 

P/N: ALF-012010A  LiFEPO4 (LFP)

LITHIUM IRON PHOSPHATE  

 

SPECIFICATIONS 

 

USER MANUAL 

 

WARRANTY  

 

CONTACT AND SUPPORT  

 

 
 

12V

 

10AH 

 

120WH

 

10A MAX DISCHARGE

 

 
 

 
 
 

 
 
 

*Subjects of this content pertains to Aegis Battery LiFEPO4 (LFP) for Deep Cycle usage only and are 
not representative of any other type, chemistry, make, and/or model of battery thereof.  

REV20220312 

LiFEPO4  10-Year,  provided,  Buyer  must  install  battery  within  six  (6)  months  after  shipment.  Aegis  Battery 
shall not be liable for any defects that are caused by neglect, improper installation or original product being 
altered or modified in any way by an entity other than Aegis Battery. On Standard products 30-day money 
back  guarantee  for  any  initial  quality  issues  originating  from  Aegis  Battery.   Only  Standard  products  are 
eligible  for  Exchange  or  Returns  subject  to  Shipping  Cost  Charges  plus  a  10%  Restock  Fee  on  Returns.  All 
Exchanges or Returns, including warranty requests must have prior approval by Aegis Battery. Upon receipt 
of  products,  Aegis Battery  has  the  right  to  inspect  product  for  Return,  Exchange  and if  defective,  that  the 
defect  is covered by  our  limited warranty  for  repair,  replace  or  prorated  credit  after  2  years  from  original 
purchase. 

Отзывы: