12.1
If the drying results are
not satisfactory
• The set programme was incorrect.
• The filter is clogged.
• The Heat Exchanger is clogged.
• There was too much laundry in the
appliance.
• The drum is dirty.
• Incorrect setting of the conductivity
sensor ( See chapter "
Settings -
Adjustment of the remaining laundry
moisture degree
" for better setting).
• The airflow slots are clogged.
• Room temperature is too low or too
high ( optimal room temperature 19°C
to 24°C )
13.
TECHNICAL DATA
Height x Width x Depth
850 x 600 x 600 mm (maximal 665 mm)
Max. depth with the appliance door open
1100 mm
Max. width with the appliance door open
950 mm
Adjustable height
850 mm (+ 15 mm - feet regulation)
Drum volume
118 l
Maximum load volume
8
kg
Voltage
230 V
Frequency
50 Hz
Sound power level
66 dB
Total power
900 W
Energy efficiency class
A++
Energy consumption on the standard cotton
programme with the full load.
1)
1,99
kWh
Energy consumption on the standard cotton
programme with the partial load.
2)
1,07
kWh
Annual energy consumption
3)
234,70 kWh
Left-on mode power absorption
4)
0,13 W
Off mode power absorption
4)
0,13 W
Type of use
Household
Allowed ambient temperature
+ 5°C to + 35°C
Level of protection against ingress of solid
particles and moisture ensured by the pro-
tective cover, except where the low voltage
equipment has no protection against mois-
ture
IPX4
This product contains fluorinated greenhouse gases, hermetically sealed
ENGLISH
19
Содержание TB5050TW
Страница 1: ...USER MANUAL EN User Manual 2 Tumble Dryer DE Benutzerinformation 26 Wäschetrockner TB5050TW ...
Страница 43: ...11 3 Reinigen des Wärmetauschers 1 2 1 2 3 4 1 1 2 2 5 6 7 8 9 2 1 DEUTSCH 43 ...
Страница 54: ...www aeg com 54 ...
Страница 55: ...DEUTSCH 55 ...