Problem
Possible cause
Solution
The thickness of the frost is
greater than 4-5 mm.
Defrost the appliance.
The door has been
opened often.
Open the door only if necessa-
ry.
There is no cold air circula-
tion in the appliance.
Make sure that there is cold air
circulation in the appliance.
If the advice does not lead
to the desired result, contact
the nearest Authorised
Service Centre.
7.2
Replacing the lamp
The appliance is equipped with a longlife
LED interior light.
Only service is allowed to replace the
lighting device. Contact your Authorised
Service Centre.
7.3
Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer to
assembly instructions.
3.
If necessary, replace the defective
door gaskets. Contact the Authorised
Service Centre.
8.
INSTALLATION
8.1
Location
Refer to the assembly
instructions for the
installation.
To ensure best performance, install the
appliance well away from sources of heat
such as radiators, boilers, direct sunlight
etc. Make sure that air can circulate freely
around the back of the cabinet.
8.2
Positioning
Install the appliance in a dry, well
ventilated indoors where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance.
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
Climate
class
Ambient temperature
T
+16°C to + 43°C
Some functional problems
might occur for some types
of models when operating
outside of that range. The
correct operation can only
be guaranteed within the
specified temperature
range. If you have any
doubts regarding where to
install the appliance, please
turn to the vendor, to our
customer service or to the
nearest Authorised Service
Centre.