40
818 20 85-01/2
If after the above checks there is still a fault, call your local AEG Service
Force Centre.
In-guarantee customers should ensure that the above checks have been
made as the engineer will make a charge if the fault is not a
mechanical or electrical breakdown.
Please note that proof of purchase is required for in-guarantee service
calls.
Regulations, Standards, Guidelines
This appliance was designed for household use and was manufactured
in accordance with the appropriate standards. The necessary measures
in accordance with appliance safety legislation regulations (GSG),
accident prevention regulations for refrigeration appliances (VBG 20)
and the regulations of the German Society of Electrical Engineers (VDE)
were observed in the manufacture of this appliance.
The refrigerant circuit has been checked for leaks.
;
This appliance is in accordance with the following EU guidelines:
– 73/23/EWG dated 19 February 1973 - low voltage guidelines.
– 89/336/EWG dated 3 May 1989
(including guideline change notice 92/31/EWG) - EMV guideline
Interior illumination does not function.
Important: The interior lighting switches
off automatically after 20 minutes.
Please refer to "Replacing the Light Bulb "
section.
Water on the floor or on storage shelves.
Water drain hole is blocked.
See the "Cleaning and Maintenance" sec-
tion.
Excessive build up of frost.
If the door seal is not airtight (probably
after reversing the door) apply warm air
to the non sealing area using a hair dryer
set to a gentle heat. (do not use a fan
heater for this purpose). This will make
the rubber more supple and allow it to
revert to its original shape.
Noise
Refer to Normal Operating Sounds
The compressor does not start
immediately after changing the
temperature setting.
This is normal, the compressor starts after
a period of time.
Symptom