69

Wall unit mounting - Fig. 6

First decide which functioning version is better for you.
If you decide to use the hood in exhausting version we suggest to position
the upper section of the chimney so that the oulet slots are not visible
once installation has ended, on the contrary if is decided to use the hood
in recycling version BE SURE that the side with slots is up (see also A-B-
C sequence on on Fig. 6).

Insert the frame, that holds controls, grease filter and lamps, in the mo-
tor housing using proper rails and fix each other with two 3x9 screws (1-
2-3)
.

Sign the wall with a center line, this will aid mounting procedure (4),
position the template so that the mid line printed on the template mat-
ches with the center line previously signed, the lower side of the temp-
late corresponds to the lower side of the hood once mounted (5).

Drill two holes Ø 8mm and fix the support bracket with two wall plugs
and screws (6).

Hang the hood (7) adjust its position (8-9) and from the inside of the
hood sign one point for definitive fixing (10), remove the hood and drill
an hole Ø 8mm (11), fit a wall plugs, hang the hood again and fix it
definitively with a screw (12).

Drill two holes Ø 8mm on the upper side close to the ceilling (13), fit two
wall plugs and fix the chimney support with two screws (14).
In case the hood is to be used in Recycling version, mount the deflector
F on the chimney support with four screws 2,9x6,5 and fit an exhausting
pipe (15) to connect deflector to the outlet hole B of the hood.
In case the hood is to be used in exhausting version, then the deflector
must not be mounted and fit an exhausting pipe (15) to connect outlet
hole B of the hood to the outside.

Make electrical connection (16), but leave the hood disconnected from
the home general electric panel.

Connect lamps and control panel to the motor housing (17).

Insert the vapour catcher on the motor housing and fix it with four screws
M4x35 (18).
Model 3010D has an additional part that can be mounted to the first
part fixed on step 18 before or after this step, choose the convenience,
fixing between this two parts must be done with four screws.

Fix the chimney first up (19a) to the chimney support (19b), then on the
bottom  (20a) to the upper side of the frame (20b) using four screws
2,9x6,5.

Connect the hood the the home general electric panel and check if the
hood work properly.

Содержание protect d. 3000

Страница 1: ...0 D 3010 D Dunstabzugshaube Afzuigkap Hotte aspirante Cooker Hood Montage und Gebrauchsanweisung Installatie en gebruiksaanwijzing Manuel de montage et d utilisation Operating and Installation Instructions ...

Страница 2: ...on 60 Maintenance and care 61 Metal grease filter Open the metal grease filter Carbon filter 62 Changing the light bulb 63 Cleaning 64 Special accessories Technical assistance service Guarantee conditions 65 Service Technic Details 67 Installation 68 Electrical connection Safety warnings for the electrician Wall unit mounting 69 ...

Страница 3: ...g replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up causing a fire hazard for kitchen unit installer When used as an extractor unit the hood must be fitted with a 150mm diameter hose Fal...

Страница 4: ...h appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 600 cm2 large to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel bu...

Страница 5: ... 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flange provided In this case the hood will be slightly more noisy Filter version The air is filtered through an activated charcoal filter and returned to the kitchen through the top grill of the outlet pipe When the hood is used in the filter version it must be fitted with an original AEG KF2...

Страница 6: ...off B Start and choice of motor speed 1 2 3 1 2 C Indicates speed 1 LED D Indicates speed 2 LED E Indicates speed 3 LED F Indicates Intensive speed LED G Intensive speed on off The Intensive speed runs for 5 minutes If the hood is on when the Intensive speed is activated the hood revert to previous speed after 5 minutes If the hood is off when the Intensive speed is activated the hood will automat...

Страница 7: ... then extract the filter pulling downwards Fig 3 Dishwasher machine Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process Refit the grease filters when it are dry When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur this does not have any impact on its performance Clean th...

Страница 8: ...n the filter and later causes bad odours To reactivate the carbon the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Remove the frame i which supports the filter h by unscrewing it from the hood g Fig 4 Insert the coa...

Страница 9: ...tor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover use a screw driver as a lever Fig 5 Replace the old bulb with a new one of the same type Remount the lamp cover If the light does not come on make sure the bulb has been inserted in correctly ...

Страница 10: ...to do so will cause grease deposits to build up that could constitute a fire hazard Special accessories Carbon filter KF20 E Nr 942 120 600 Technical assistance service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code numbe...

Страница 11: ...sed agent AEG reserves the right to stipulate the place of the repair i e the customer s home place of installation or AEG workshop 4 The guarantee or free replacement includes both labour and materials 5 Repairs carried out under guarantee do not extend the guarantee period for the appliance Parts removed during guarantee repairs become the property of AEG 6 The purchaser s statutory rights are n...

Страница 12: ... of your new home They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances France Senlis 33 0 44 62 29 29 Germany Nürnberg 49 0 911 323 2600 Italy Pordenone 39 0 1678 47053 Sweden Stockholm 46 0 8 738 7910 UK Slough 44 0 1753 219899 ...

Страница 13: ...th x Depht in cm 755 1220 x 898 x 500 Maximum absorbed power 210 W Motor absorption 1 x 170 W Lighting 2 x20 W Lenght of the cable 150 cm Fan powers speed speed in compliance with DIN 44971 Extractor version Speed 1 171 m3 h 2 268 m3 h 3 291 m3 h i 435 m3 h Filter version Speed 1 118 m3 h 2 176 m3 h 3 201 m3 h i 267 m3 h Flange 150 mm Ø ...

Страница 14: ...stance of at least 3 mm between contacts must be provided This disconnector may be for example a switch fuses plug fuses must be removed from the fuse box fault current switches and remote switches with a distance of over 3 mm between contacts The manufacture declines all responsibility for malfunctions resulting from failure to comply with the above instructions If the power socket is applied dir...

Страница 15: ... 11 fit a wall plugs hang the hood again and fix it definitively with a screw 12 Drill two holes Ø 8mm on the upper side close to the ceilling 13 fit two wall plugs and fix the chimney support with two screws 14 In case the hood is to be used in Recycling version mount the deflector F on the chimney support with four screws 2 9x6 5 and fit an exhausting pipe 15 to connect deflector to the outlet h...

Страница 16: ...70 20b 12 19b 19b 7 7 4 5 6 8 9 13 13 14 15 19a 9 8 16 8 9 10 11 20a 20a 20b 19a 17 18 18 18 F G H 1 2 3 A B 180 C OK B Fig 6 Model 3010D ...

Страница 17: ...AEG Hausgeräte GmbH Postfach 1036 D 90327 Nürnberg http www aeg hausgeraete de Copyright by AEG LI1M7B Ed 05 01 ...

Отзывы: