Frontloading Washingmachines Range 1997
5 6
GGI
h/h1/Wav/AEG_p46/technik/folien/epw/folepw/11.02.1997
05.97
HV831-N
Fault indication in multidisplay and / or in programe progress display
Display
Type of fault
Programe knob position
Remedy
C7
12
not heating
delicate wash 30 °C
replace element
12
heating relais defect
delicate wash 30 °C
replace heating relais
12
heat element connection defect
delicate wash 30 °C und
12
fTR-pressure switch defect
monitor programe cycle
replace pressure switch
12
valve always lets water through
delicate wash 30 °C
change valve
Fault indication is only cleared by customer service programe and rectification ; Programe stops ;
1
Programe continues.
Fault indicated at the end of programe.
2
Fault indication can be cleared by customer. Start button is flashing.
Fault is stored (protected against main short circuit)
3
Programe continues.Fault indicated only in the customer service programe.
13. Service test programe