AEG OKO FAVORIT 80800 Скачать руководство пользователя страница 6

The circulation pump, wash and heating   
The circulation pump is driven by a single phase asynchronous motor with a 4mF 
Capacitor connected to the start winding. 
 
Different speeds are used during the wash cycle, (depending upon which part of 
the program is being performed).   
These speeds are controlled by a Tachometric generator fitted on the end of the 
motor. 
 
During parts of the program a pulsed wash action is used, eg, (last hot rinse). 
This pulsed wash action runs: 
         4 seconds at  1600 rpm 
         0.8 seconds at 2800rpm  
 
The diverter valve allows the water to be alternated between the upper spray arm 
and the  ceiling spray arms.  
During the heating steps the water is only supplied to the upper spray arm.  

 
 
Circulation pump and  
          Diverter valve                           

 

 
 
 
 
The Heater 
 
A 2100 watt tubular heater is situated in the base of the appliance.  
During the heating steps the water is directed only to the upper spray arm. 
The resistance is 25  

Содержание OKO FAVORIT 80800

Страница 1: ...SERVICE MANUAL DISHWASHER Favorit 80800 Produced by Electrolux Technical Department ...

Страница 2: ...the control panel The program start can be delayed by up to 19 hours Digital display showing Program run time Delay time Softener setting Fault codes Recognition of the middle spray arm under upper basket not rotating At the end of the program the middle spray arm stops at the same position 220º to ensure no water left in the arm will run onto the dry crocks Turbo fan drying Interior light operate...

Страница 3: ...selected program The setting of the water softener If the end of program tone is on or off The length of time set for the program delay start Fault codes Above the multi display is the button for setting the program start delay To the right of the multi display are the program phase indicators When a program is first selected all the phase indicators are illuminated Once the pro gram starts only t...

Страница 4: ...rrect setting has been made press the ON OFF button to switch the machine off The new setting will now be saved The water hardness is shown in the customers handbook in German degrees and Parts per million Setting the End of Program audible signal Press and hold the Auto 65º and the Auto Bio 50º buttons Press the ON OFF button the two program lamps will flash Pushing the Auto 65º button will indic...

Страница 5: ...ioned by a very weak magnet in one end of the middle spray arm As the magnet at the end of the spray arm passes the Hall sensor a voltage of 4 5 volts is generated which is monitored at the electronic If the electronic does not detect 4 revolutions in 40 seconds the spray arm LED illuminates and the buzzer sounds Hall sensor for spray arm ...

Страница 6: ...r During parts of the program a pulsed wash action is used eg last hot rinse This pulsed wash action runs 4 seconds at 1600 rpm 0 8 seconds at 2800rpm The diverter valve allows the water to be alternated between the upper spray arm and the bottom ceiling spray arms During the heating steps the water is only supplied to the upper spray arm Circulation pump and Diverter valve The Heater A 2100 watt ...

Страница 7: ...out at the end of the pre wash and will use the same water for the main wash This measurement also takes place during the first rinse If the water is found to be dirty another rinse is added however if the water is clean only one rinse will be performed The Turbidity sensor is re calibrated during the final rinse of each cycle Because engineers cannot test this part no values are given however sho...

Страница 8: ...minutes into heating If a half load is detected the following occurs Main wash time reduced by between 4 and 6 minutes depending on the program No second rinse in the INTENSIVE 70º program The rinses could be reduced by approximately 2 minutes The temperature of the last hot rinse reduced by 5º This does not apply to the Auto bio 50º and the Normal bio 50º programs Programs with Fuzzy Detection of...

Страница 9: ...º No No No 40º Cold No 55º No Prewash No No Cold No No No No No Program functions This function is dependant on Fuzzy logic load detection see page 7 These functions are dependent upon the Turbidity of the water A short 18 minute test program can be run to check all the machines Components This program is selected in the following way The machine must be off and there must be no wash load Press an...

Страница 10: ...m filling circulation 4 pause 15 Dynamic filling Level controlled 2800 rpm filling circulation variable Dynamic filling Level controlled 2800 rpm filling circulation Diverter to upper position 5 Dynamic filling Level controlled 2800 rpm filling circulation Detergent disp Variable max 1200 sec dynamic filling Level controlled to 50º C or 1200 sec 2800 rpm filling circulation heating 60 2800 rpm Cir...

Страница 11: ...ll flash Push the Auto 65º button Each individual componet will operate for 5 seconds in the following order 1 Inlet valve 2 Regeneration valve 3 Circulation pump 4 Diverter valve 5 Drain pump 6 Turbo drying fan and flap 7 Detergent dispenser After 2 minutes the test will automatically terminate Alternatively switch the machine off with the ON OFF button Please Note The heater is not operated duri...

Страница 12: ...ed by the door Aqua control float switch C3 Drying End 3 times Drain pump is working although it is not selected by PCB Program stops and restarts automatically once the fault is rectified Acoustic signal is interrupted by opening the door C4 Final rinse Turbidity sensor C5 Final rinse end 5 times Turbidity signal can not re calibrate Turbidity detected cycle run is adapted accordingly C6 Final ri...

Страница 13: ...will stop water continues until the pressure switch is made Diverter valve Cb Rinsing Drying End 11 times a Diverter valve not in required position within 4 3 minuets b Diverter valve changes position without selection from the PCB Cycle continues Heating steps will be eliminated Program Error with Forming variant Cf Washing End 15 times Fault within the electronics No program selection possible O...

Страница 14: ...ton The LEDs flash for the Auto 65 and the Normal 65 programs Push the Intensive 70 button The fault code will be displayed To cancel fault code in the memory Press and hold Auto 65 and Normal 65 program buttons Switch the machine on with the ON OFF button The LEDs flash for the Auto 65 and the Normal 65 programs Press the Auto 65 program button The fault codes will be deleted ...

Страница 15: ...istance 3750 4000 Heating element Power input 2100 watts Resistance 25 Protector 98ºC 5º Thermal fuse 260ºC Circulation Pump Capacitor 4 F Power input output 100 watts 50 watts Speed 1600rpm 2800rpm Current input 0 6amps Main winding resistance 50 5 Auxillary winding resistance 160 Tacho winding resistance 213 Diverter valve Rotary speed 0 5rpm Resistance 9300 Pressure switch Switch on off fn 65mm...

Страница 16: ...hardness shows the hardness before passing through the softener and the residual water hardness shows the hardness after the water has passed through the softener The table shown below appears in the customer s handbook ºd German degrees ppm parts per million factory setting ...

Страница 17: ...Technical Specifications continued ...

Страница 18: ...Wiring Diagram ...

Страница 19: ...Wiring Plan ...

Страница 20: ...Legends ...

Отзывы: