45
Installation - for contractors
Note
An outlet temperature of 50 °C can be achieved with
the lowest possible flow rate and the following cold
water inlet temperatures:
◦
MTE 350 > 17 °C
◦
MTE 440 > 18 °C
◦
MTE 570 > 13 °C
◦
MTE 650 > 8 °C
15.4
Application areas
For the specific electrical resistance and
specific electrical conductivity, see "Data
table".
Standard specifica
-
tion at 15 °C
20 °C
25 °C
Spec.
resist-
ance
ρ ≥
Spec. conduc-
tivity σ ≤
Spec.
resist-
ance
ρ ≥
Spec. conduc-
tivity σ ≤
Spec.
resist-
ance
ρ ≥
Spec. conduc-
tivity σ ≤
Ωcm
mS/m
μS/cm
Ωcm
mS/m
μS/cm
Ωcm
mS/m
μS/cm
1000
100 1000
890
112 1124
815
123 1227
1300
77
769
1175
85
851 1072
93
933
15.5
Details on energy consumption
Product data complies with EU regulations relating to the Directive on the ecodesign of energy related products (ErP).
MTE 350
MTE 440
MTE 570
MTE 650
231003
231004
231216
232770
Manufacturer
AEG Haustechnik
AEG Haustechnik
AEG Haustechnik
AEG Haustechnik
Load profile
XXS
XXS
XXS
XXS
Energy efficiency class
A
A
A
A
Annual power consumption
kWh
478
478
478
Energy conversion efficiency
%
39
39
39
40
Sound power level
dB(A)
15
15
15
15
Special information on measuring efficiency
None
None
None
None