TROUBLESHOOTING
CAUTION!
Refer to the chapters on safety.
8.1
What to do if…
Problem
Possible cause
Solution
The pouch is not
sealed correctly.
The sealing time is not correct.
Change the sealing time.
The cover gasket is dirty or worn. Clean or replace the cover gasket
(contact the Technical Assistance
Service for a replacement).
The pouch is not placed correctly
on the sealing bar.
Position the pouch correctly.
The sealing bar is worn (the
Teflon coating is burnt).
Replace the sealing bar (contact
the Technical Assistance Service
for a replacement).
The blade placed under the
Teflon of the sealing bar is
broken.
Replace the blade (contact the
Technical Assistance Service for a
replacement).
Final vacuum is
poor.
The set vacuum level is not
correct.
Change the vacuum level.
The cover gasket is dirty or worn. Clean or replace the cover gasket
(contact the Technical Assistance
Service for a replacement).
The cover is not closed correctly. Close the cover correctly.
Make sure that objects or dirt are
not found between the cover and
tank.
The cover does
not open.
No power supply.
Wait until the power supply is
restored.
The cover is
cracked or
broken.
Damaged cover.
Replace the cover (contact the
Technical Assistance Service for a
replacement).
The and
buttons flash.
“Reconditioning cycle”
in progress.
Wait for the end of the
“reconditioning cycle” (15
minutes).