background image

A

B

A.

Outlet

B.

Inlet

Assembly of regulator

To assembly the regulator to the

cooktop use the elbow and washer

supplied with the appliance.
The ½" parallel thread connects to the

end of shaft with nut. The washer is

placed between the end of shaft and the

elbow.
The ½" tapered thread connects to the

outlet of the regulator, and is sealed on

the thread. Use thread sealing tape or

thread sealing compound.
The inlet of the regulator is a ½” parallel

thread and is connected to consumer

piping or hose assembly.

The regulators are

configured for use with

Natural Gas. It is not

required to adjust the

regulator to obtain correct

outlet pressure setting.

When the inlet and outlet is

orientated correctly the

arrow on the base of the

regulator indicates the

direction of gas flow.

Checking the gas supply

It takes additional time to

light the gas for the first

time. Air is purged from the

pipes.

1.

Check the manometer zero point is

correct.

2.

Connect the manometer to the

cooktop pressure point. It is located

on the regulator.

3.

Turn on the gas supply and

electricity, and try to ignite the gas.

4.

While the appliance operates check

the outlet pressure:

• when all burners of the appliance

operate at maximum,

• when the smallest burner of the

appliance operates at minimum.

The outlet pressure should

not vary from the nominal

outlet pressure of 1.00kPa by

more than +/–0.20kPa.

Checking the regulator

If the regulator works incorrectly:
• Adjust of upstream regulator if the

outlet and inlet pressure is too low or

an upstream regulator or valve with

insufficient flow capacity is present in

the gas supply line.

Check again the inlet and outlet

pressure, the inlet pressure needs to

be 1.13 - 5kPa.

• Check if the inlet and outlet is

orientated correctly the arrow on the

base of the regulator indicates the

direction of gas flow.

If the regulator still does not

work correctly contact the

After Sales Service.

WARNING!

Check if the hose assembly

is restrained from accidental

contact with the flue outlet

of an oven or any other hot

surface of an adjacent

appliance.

9.3 

Gas Conversion

1.

Remove the pan supports.

2.

Remove the caps and crowns of the

burner.

3.

Remove the injectors and replace

them with the ones which are

necessary for the type of gas you use

(see table in "Technical Information"

chapter).

ENGLISH

15

Содержание HG975550

Страница 1: ...USER MANUAL EN User Manual Hob HG975550 ...

Страница 2: ...shooter service information www aeg com webselfservice Register your product for better service www registeraeg com CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised Service Centre ensure that you have the following data available Model PNC Serial Number The information can be found on the rating plate Warning Caution Safety information General information an...

Страница 3: ...hall not carry out cleaning and user maintenance of the appliance without supervision Children aged 3 years and under must be kept away from this appliance when it is in operation at all times 1 2 General Safety WARNING The appliance and its accessible parts become hot during use Care should be taken to avoid touching heating elements Children less than 8 years of age shall be kept away unless con...

Страница 4: ... authorized Service or similarly qualified persons in order to avoid a hazard Where the appliance is directly connected to the power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed The earth cable is excluded from this When you route the mains cable make sure that th...

Страница 5: ...ufficient for air circulation The bottom of the appliance can get hot Make sure to install a non combustible separation panel under the appliance to prevent access to the bottom 3 2 Electrical Connection WARNING Risk of fire and electrical shock All electrical connections should be made by a qualified electrician The appliance must be earthed Before carrying out any operation make sure that the ap...

Страница 6: ...g and protective film if applicable before first use Use this appliance in a household environment Do not change the specification of this appliance Make sure that the ventilation openings are not blocked Do not let the appliance stay unattended during operation Set the cooking zone to off after each use Do not put cutlery or saucepan lids on the cooking zones They can become hot Do not operate th...

Страница 7: ... Do not use or store flammable materials in the appliance storage drawer or near the appliance Do not use the appliance as a space heater Do not let large cookware to overhang the cooktop onto the adjacent worktop It cause scorching to the worktop surface Do not put cooking pots or pans close to the controls This appliance complies with the requirements of Australian Standard AS5263 1 1 3 5 Care a...

Страница 8: ...ol Description no gas supply off posi tion Symbol Description ignition position maxi mum gas supply minimum gas supply 5 DAILY USE WARNING Refer to Safety chapters 5 1 Burner overview A B D C C D A B A Burner cap B Burner crown C Ignition candle D Thermocouple 5 2 Ignition of the burner Always light the burner before you put on the cookware www aeg com 8 ...

Страница 9: ...ob counter clockwise to maximum gas supply position and push it down Keep the control knob pushed for equal or less than 10 seconds to let the thermocouple warm up If the burner accidentally goes out turn the control knob to the off position and try to light the burner again after minimum 1 minute The spark generator can start automatically when you switch on the mains after installation or a powe...

Страница 10: ...t the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid 6 3 Diameters of cookware Use cookware with diameters applicable to the size of burners Burner Diameter of cookware mm Multi Crown 180 260 Semi rapid rear left 120 240 Semi rapid rear right 120 240 Semi rapid front right 120 220 Auxiliary 80 180 7 CARE AND CLEANING WARNING Refer to Safety chap...

Страница 11: ...osition they are put on metal pins installed in the rear side of the hob For easier cleaning pan supports can be removed from the hob Lift up the pan supports keeping them in horizontal position and with the right order as shown in the graphic Do not lift the pan supports at an angle as this will put strain on the metal pins This can cause damage to the pins and cause them to break 1 1 2 1 2 1 2 T...

Страница 12: ...the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a quali fied electrician Burner cap and crown are placed incorrectly Place the burner cap and crown correctly The flame extinguishes im mediately after ignition Thermocouple is not heated up sufficiently After lightning the flame keep the knob pushed for equa...

Страница 13: ...m of the hob The bottom of the appliance can get hot Ensure a non combustible separation panel under the appliance is installed to prevent access to the bottom A clearance of 20mm is required from the bottom of the appliance to the separation panel Model PNC Serial number Check if the appliance is installed in accordance with clauses 6 2 5 and 6 10 1 1 of AS NZS 5601 1 2013 or clauses 6 10 1 and 6...

Страница 14: ...this information in conjunction with the length of run number of elbows tees and bends the available service pressure and the supply requirements of other installed appliances to determine a suitable pipe size For assistance in this matter refer to the appropriate section of AS NZS 5601 1 or AS NZS 5601 2 An AGA certified class B or D flexible connection can be used to connect the cooktop in accor...

Страница 15: ... electricity and try to ignite the gas 4 While the appliance operates check the outlet pressure when all burners of the appliance operate at maximum when the smallest burner of the appliance operates at minimum The outlet pressure should not vary from the nominal outlet pressure of 1 00kPa by more than 0 20kPa Checking the regulator If the regulator works incorrectly Adjust of upstream regulator i...

Страница 16: ... pressure when all burners of the appliance operate at maximum when the smallest burner of the appliance operates at minimum The outlet pressure should not vary from the nominal outlet pressure of 2 60kPa by more than 0 52kPa A B D C top hat nut assembly fully screwed down turn top hat nut anticlockwise and remove configuration for natural gas H G F E configuration for LPG If the regulator works i...

Страница 17: ...mains cable and a plug Always use a correctly installed shockproof socket Make sure that there is an access to the mains plug after the installation Do not pull the mains cable to disconnect the appliance Always pull the mains plug There is a risk of fire when the appliance is in connection with an extension cable an adapter or a multiple connection Make sure that the ground connection agrees with...

Страница 18: ...es are for the distances to combustible surfaces If the surfaces is not combustible the measurements can be smaller that shown 4 50 mm 400 mm If a furniture unit is installed at a distance of 400 mm above the hob there must be a minimum safety distance of 50 mm to the left or right from the edge of the hob 5 6 7 B A A supplied seal www aeg com 18 ...

Страница 19: ...ger or much smaller than expected If you can not solve the problem contact the After Sales Service 3 Check the turndown minimum or low setting on each burner it may need adjustment Valves have a bypass controlling screw which you can accessed by removing the knob Bypass are set at the factory for use on natural gas and should not require adjustment If the appliance is converted to LPG screw the by...

Страница 20: ...acement with Universal LPG 2 75 kPa 2 60 kPa 34 9 MJ h Electric supply 220 240 V 50 60 Hz Gas connection R 1 2 Appliance class 3 10 4 Gas burners for NATURAL GAS 1 0 kPa BURNER GAS CONSUMPTION MJ h INJECTOR MARK Multi Crown 14 3 175 Semi rapid 9 0 135 Auxiliary 5 1 100 10 5 Gas burners for U LPG 2 60 kPa BURNER GAS CONSUMPTION MJ h INJECTOR MARK Multi Crown 12 4 96A Semi rapid 6 4 71 Auxiliary 3 3...

Страница 21: ...iners to recycle it Help protect the environment and human health by recycling waste of electrical and electronic appliances Do not dispose of appliances marked with the symbol with the household waste Return the product to your local recycling facility or contact your municipal office ENGLISH 23 ...

Страница 22: ...faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or inappropriate operation viii insect or vermin infestation ix failure to comply with any additional instructions supplied with the Appliance In add...

Страница 23: ...www aeg com shop 867334759 B 262017 ...

Отзывы: