Auxiliary burner:
1.0 kW
TOTAL POWER:
G20 (2H) 20 mbar = 10.5 kW
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Electric supply:
230 V ~ 50 Hz
3 core flexible cable with non rewireable plug fitted
with a 3 amp cartridge fuse
Category:
II2H3+
Gas connection:
R 1/2"
Gas supply:
G20 (2H) 20 mbar
Appliance class:
3
By-pass diameters
Burner
Ø By-pass in
1/100 mm
Auxiliary
28
Burner
Ø By-pass in
1/100 mm
Semi-rapid
32
Triple Crown
56
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
inj. 1/100 mm
Auxiliary
1.0
70
Semi-rapid
1.9
96
Triple Crown
3.8
146
Gas burners for LPG (Butane / Propane) G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
inj. 1/100
mm
G30
28-30
mbar
G31
37 mbar
g/h
g/h
Auxiliary
1.0
50
73
71
Semi-rapid
1.9
71
138
136
Triple Crown
3.8
98
276
271
10.
ENVIRONMENT CONCERNS
Recycle the materials with the
symbol . Put the packaging in
applicable containers to recycle it.
Help protect the environment and
human health and to recycle waste
of electrical and electronic
appliances. Do not dispose
appliances marked with the symbol
with the household waste. Return the
product to your local recycling
facility or contact your municipal
office.
16 www.aeg.com