8.8
Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 450 mm
30 mm
B
A
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.9
Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9.
TECHNICAL INFORMATION
9.1
Hob dimensions
Width
740 mm
Depth
510 mm
9.2
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Triple Crown
56
Semi-rapid
32
Auxiliary
28