BURNER
Ø BYPASS 1/100 mm
Semi-rapid
42
Auxiliary
32
9.3
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 11.4 kW
Gas replacement:
G30 (3+) 28-30 mbar = 825 g/h
G31 (3+) 37 mbar = 811 g/h
Electric supply:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category:
II2H3+
Gas connection:
R 1/2"
Appliance class:
3
9.4
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Triple Crown
4,0
1,4
146
Rapid
2,4
0,75
108x
Semi-rapid
2,0
0,75
96x
Auxiliary
1,0
0,45
70
9.5
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 4,0
1,4
98
291
286
Rapid
2,35
0,95
79
171
168
Semi-rapid
2,0
0,75
71
145
143
Auxiliary
1,0
0,45
50
73
71
www.aeg.com