9.
TECHNICAL INFORMATION
Hob dimensions
Width:
595 mm
Length:
525 mm
Hob recess dimensions
Width:
560 mm
Length:
480 mm
Heat input
Triple Crown burner:
4.0 kW
Semi-Rapid burner:
2.0 kW
Auxiliary burner:
1.0 kW
TOTAL POWER:
G20 (2H) 20 mbar = 9 kW
G30 (3+) 28–30 mbar = 654 g/h
G31 (3+) 37 mbar = 643 g/h
Electric supply:
230 V ~ 50 Hz
Category:
II2H3+
Gas connection:
G 1/2
Gas supply:
G20 (2H) 20 mbar
Appliance class:
3
By-pass diameters
Burner
Ø By-pass in
1/100 mm
Burner
Ø By-pass in
1/100 mm
Auxiliary
28
Triple Crown
56
Semi-rapid
32
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
inj. 1/100 mm
Auxiliary
1.0
70
Semi-rapid
2.0
96
Triple Crown
4.0
146
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
inj.
1/100 mm
G30
28-30 mbar
G31
37 mbar
g/h
g/h
Auxiliary
1.0
50
73
71
Semi-rapid
2.0
71
145
143
14 www.aeg.com
Содержание HG654421
Страница 76: ...www aeg com shop 892962040 A 472013 ...