AEG HG60FXA Скачать руководство пользователя страница 8

8

INSTRUCTIONS FOR THE INSTALLER

Natural Gas. The appliance installer is not required 

to make an adjustment to obtain the correct outlet 

pressure setting.

An arrow on the base of the regulator indicates 

the direction of gas flow when the inlet and outlet 

of the regulator is orientated correctly. When the 

regulator has been fitted check for leaks from the 

connections with soapy water.

Gas Connection

This appliance is supplied for use with Natural 

Gas. However, it can be converted for use with 

LPG. Refer to LP conversion chapter.

Supply pipe sizing

The total hourly gas consumption for the appliance 

is shown on the data label. The required supply 

pressure (i.e. at inlet to appliance regulator) for 

each gas type is shown on the data label, and 

given in page "TECHNICAL CHARACTERISTIC 

TABLES". Use this information in conjunction with 

the length of run, number of elbows, tees and 

bends, the available service pressure and the 

supply requirements of other installed appliances 

to determine a suitable pipe size. For assistance 

in this matter refer to the appropriate section of the 

Installation Code AS5601.

An AGA certified class B or D flexible connection 

may be used to connect the cooktop in accordance 

with the AS5601 and in particular section 4.8. 

Where a hose assembly is used and the cooktop 

is in the installed position, the hose assembly shall 

be suitable for connection to a fixed consumer 

piping outlet located at a point 800 - 850mm above 

the floor and in the region outside the width of the 

appliance to a distance of 250mm. The point of 

connection to consumer piping must be accessible 

with appliance installed.

Elbow positioning

It is possible to reposition the elbow if required by 

loosening the locking nut and elbow by using two 

spanners. Re-tighten the entire assembly after the 

elbow has been repositioned. When fitting elbow to 

appliance, ensure that the sealing washer is fitted.

Regulator

An appliance regulator is provided. The regulator 

must be positioned so that the pressure test nipple 

is accessible when the appliance is installed. 

Connect the gas supply to the ½” B.S.P. internal 

thread inlet of the regulator (fig.7). 

Assembly of Regulator

The assembly of the regulator to the cooktop 

manifold is achieved via the elbow union and 

sealing washersupplied.

The ½” parallel thread connects to the manifold, and 

the sealing washer is placed between the manifold 

end and the flat face on the elbow.

The ½” tapered thread connects to the outlet of the

regulator, and is sealed on the thread using 

approved thread sealing tape or approved thread 

sealing compound.

The inlet of the regulator is a ½” parallel thread and

is connected to consumer piping or hose assembly.

Regulators are supplied pre-adjusted and 

configured by the component maker for use with 

Natural Gas.

The appliance installer is not required to make an 

adjustment to obtain the correct outlet pressure 

setting.

An arrow on the base of the regulator indicates the 

direction of gas flow when the inlet and outlet of the 

regulator is orientated correctly. When the regulator 

has been fitted check for leaks from the connections 

with soapy water.

Checking the gas supply

1.  Check the manometer zero point is correct.

2.  Connect the manometer to the cooktop 

pressure point. This is located on the 

regulator.

3.  Turn on the gas supply and electricity and try 

to ignite the gas. NOTE! lt will take additional 

time to light the gas for the first time as air 

needs to be purged from the pipes.

4.  With the appliance operating check the outlet 

pressure

• 

when all burners of the appliance are 

operating at maximum,

• 

when the smallest burner of the appliance is 

operating at minimum.

Under these conditions the outlet pressure should 

not vary from the nominal outlet pressure of 

1.00kPa by more than ± 0.20kPa

If the regulator appears to not perform 

satisfactorily, then check the following points:

1.  If the outlet pressure is consistently too low 

then the inlet pressure may be too low and 

adjustment of an upstream regulator may be 

needed, or an upstream regulator or valve 

with insufficient flow capacity may be present 

in the gas supply line. If this is suspected then 

it may be necessary to repeat fhe checks 

whilst measuring both the inlet and outlet 

pressure to determine if the inlet pressure is 

in the range 1.13 - 5kPa.

2.  Check that the regulafor has been fitted to the 

gas supply line in the correct orientation, the 

arrow on the base of the body indicates the 

direction of gas flow.

Содержание HG60FXA

Страница 1: ...EN User Manual Hob USER MANUAL HG60FXA HG75FXB HG90FXB HG90FX MB ...

Страница 2: ......

Страница 3: ...l cord or assembly available from the manufacturer or its service agent Before carrying out the maintenance or cleaning the equipment cut off power supply and allow it cool down Make sure that air circulates around the gas equipment Insufficient ventilation produces a lack of oxygen In case of an intense or prolonged use of the equipment it may be necessary to improve aeration for example by openi...

Страница 4: ...must be chosen between the maximum and the minimum ones never between the minimum position and the closing point The gas supply can be interrupted by turning the knob clockwise up to the closing position If there is no power supply it is possible to light the burners with matches setting the knob to the start up point large flame fig 1 BURNERS Power MJ h Ø of cookware NG LPG Auxiliary 3 4 3 4 10 1...

Страница 5: ...nding to lift Flame ports blocked or wet Clean or dry flame ports Burner incorrectly fitted Ensure this component is fitted correctly Flames not staying on when knob released Knob not held down long enough in High position for flame safeguard where fitted to engage Repeat lighting procedure and hold knob d o w n f o r 6 s e c o n d s i n H i g h p o s i t i o n refer page 4 Knob not set between Hi...

Страница 6: ...g the hob It is advisable to clean the appliance when it is cold Enamelled parts The enamelled parts must be washed with a sponge and soapy water or with a light detergent Do not use abrasive or corrosive products Do not leave substances such as lemon or tomato juice salt water vinegar coffee and milk on the enamelled surfaces for a long time Stainless steel parts Stainless steel can be stained if...

Страница 7: ...installed on the top of a built in oven without forced cooling ventilation proper air vents must be installed to guarantee an adequate ventilation with the lower air entering with a cross section of at least 200cm2 and the higher air exiting with a cross section of at least 60 cm2 Fastening the top Every cook top is equipped with a special washer A set of hooks is also supplied for mounting the co...

Страница 8: ...e regulator fig 7 Assembly of Regulator The assembly of the regulator to the cooktop manifold is achieved via the elbow union and sealing washersupplied The parallel thread connects to the manifold and the sealing washer is placed between the manifold end and the flat face on the elbow The tapered thread connects to the outlet of the regulator and is sealed on the thread using approved thread seal...

Страница 9: ... enclosed Act as follows remove the racks and burners by means of a straight spanner L unscrew the injectors U fig 8 8 A and substitute it with the corresponding one Please note the wok burner on models HG75FX M and HG90FX M has three injectors refer U1 U2 of Figure 7 A for positions tighten the injectors strongly After changing the injectors it is necessary to eliminate residual natural gas in th...

Страница 10: ...IMUM OUTER RING MINIMUM INNER RING CLOSED OUTER RING MAXIMUM INNER RING CLOSED OUTER RING MAXIMUM INNER AND OUTER RING Note that the dotted line section shown above is the transition between the operating zones It is recommended not to leave the knob in this position ...

Страница 11: ...11 8 9 9 A F 10 10 A C U2 U1 8 A For the external ring For the internal ring 7 ...

Страница 12: ...s Connection Electrical Supply Cord 610 70 890 510 2 4 2 2 8 3 MODEL HG90FXB MODEL HG90FX MB NG Universal LPG 2 Semi rapid burner 6 3 MJ h 5 6 MJ h 3 Auxiliary burner 3 4 MJ h 3 4 MJ h 4 Triple ring burner 21 6 MJ h 21 6 MJ h 5 Double ring burner 10 3 MJ h 9 6 MJ h 8 Control knob for burner MODEL A mm B mm HG60FXA 27 65 HG75FXB 35 60 HG90FXB HG90FX MB 35 60 A B ...

Страница 13: ...d long service life Wash with warm soapy water and rinse with clean water Where the stainless steel has become extremely dirty with signs of surface discolouration due to periods of neglect or misuse use a stainless steel cleaner We recommend Hillmark Steel Power cleaner for removing baked on food or stubborn build up and reducing discolouration Available from https shop aegaustralia com au DO NOT...

Страница 14: ...2 turn 6 3 3 AUXILIARY Universal LPG 2 75 52 27 3 4 Natural 1 00 80 1 4 turn 3 4 4 DOUBLE WOK CROWN Universal LPG 2 75 50 83 x2 60 21 6 Natural 1 00 80 150 x2 1 3 turn inner 1 turn outer 21 6 5 DOUBLE WOK CROWN Universal LPG 2 75 85 60 9 6 Natural 1 00 145 Adjust 10 3 MODEL HG60FXA MODEL HG75FXB HG90FXB HG90FX MB IGNITION GENERATOR TRIPOLAR TERMINAL MICRO UNIT IGNITION GENERATOR TRIPOLAR TERMINAL ...

Страница 15: ...THE MINI TRIVET The mini trivet included with this cooktop is to be used for cooking vessels of diameter 120mm or smaller Correct fitment Examples of positioning of mini trivet MODEL HG60FXA MODEL HG75FXB MODEL HG90FXB HG90FX MB ...

Страница 16: ...er Correct fitment Examples of positioning cast iron wok trivet MODELS HG75FXB HG90FXB HG90FX MB Please note the step of the trivet fingers on the wok burner main trivet applicable for models HG75FXB HG90FXB and HG90FX MB To avoid spillages lift and move cooking receptacles to and from this burner rather than sliding across the trivets ...

Страница 17: ...r faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or inappropriate operation viii insect or vermin infestation ix failure to comply with any additional instructions supplied with the Appliance In a...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...COD 208685 02 24 11 2020 ...

Отзывы: