you must fit an applicable pressure
adjuster on the gas supply pipe.
3.6 Adjustment of minimum
level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A for external
crown and B for internal crown).
A
B
5. If you change:
• from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn for
internal crown (B) and
approximately 1/3 of a turn for
external crown (A).
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
3.7 Electrical connection
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug (if applicable).
• The appliance must not be connected
with an extension cable, an adapter or
a multiple socket. There is a risk of
fire.
• Do not let the power cable to heat up
to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the
cabinet, in order to avoid any contact
with the equipment beneath the
cooktop.
Electrical Requirements
Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations.
For your own safety the installation must
be done by a qualified electrician (e.g.
your local Electricity Board, or a
contractor who is on the roll of the
National Inspection Council for Electrical
Installation Contracting [NICEIC]).
The manufacturer refuses
to be held responsible, if
these safety measures are
not abided by.
Supply connections
This hob has to be connected to 230/400
V 3N ~ 50 Hz electricity supply.
Please see the connection
details next to the terminal
block.
Before carrying out the connection, make
sure:
1. The limiter valve and the electrical
system can take the appliance load
(see the rating plate)
2. The supply system is equipped with
an efficient earth connection in
compliance with the current
standards and regulations
3. The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.
You must purchase and install the power
cable. Use only a connection cable of
type H05V2V2-F T90 or its equivalent.
Make sure that the cable section is
applicable to the voltage load and the
working temperature.
The wires in the cord are coloured as
follows:
Green and yellow
- Earth
Blue
- Neutral
Brown
- Live
www.aeg.com