Only trained and authorised experts must install the device and make the electrical connection under full 

observance of these installation instructions.

2.1 

Equipment layout 

A

 

-

 

N

1 Output selector

12 Heating system

2 Device cap

13 Type plate

3 Lower section, back panel

14 Mounting bracket

4 DHW compression fitting

15 Stud for mounting bracket

5 Cold water compression fitting

16 Cable grommet (power cable from above/below)

6 Top, back panel

17 Twin nipple (cold water with shut off valve)

7 Power switch unit

18 Flat packing

8 Safety pressure limiter (AP 3) with reset 

button

19 Screws/rawl plugs for fixing the back panel 

in case of water connection on finished walls

9 Mains terminal

20 Installation template

10 Knock-out for power connection from above

21 Installation and operating instructions

11 Fixing toggle

22 Sieve
23 Support panel (only when installing taps for 

finished walls)

2.2 

Brief description

This hydraulically regulated instantaneous water heater is a pressure device for the heating of cold water to 

DIN 1988 that can supply one or several draw-off points. 

The PinControl throughput control unit compensates for fluctuations in pressure and thus achieves largely 

stable temperatures. The PinControl limits the throughput and thus ensures a sufficient rise in the DHW 

temperature - even in winter.
The hydraulic control system regulates the electrical output automatically in two output stages, subject to the 

throughput (see Table 2 "Specification").
The bare wire heating system is enclosed within a pressure-tested plastic jacket. The heating system is also 

particularly suitable for water with low limescale or with limescale content (see Table 3 "Application areas").

2.3 

Important information

• 

Air in the cold water supply can destroy the bare wire heating system inside the equipment or can trip 

the safety system. If the water supply to the instantaneous water heater has been interrupted, e.g. 

because of a risk of frost or work on the water system, take the following measures prior to taking the 

equipment back into use:

1.  Remove fuses or trip the appropriate MCBs.
2.  Repeatedly open and close a tap downstream of the equipment long enough to vent all air from 

the equipment and its cold water supply line upstream.

3.  Replace the fuses or reset the relevant MCBs.

•  Taps/valves
  –  Direct draw-off tap for instantaneous water heater ADEo 70 WD - mono-lever mixer with bath/ 

  hand shower changeover, part no. 18 39 34. 

–  Installation with commercially available mains pressure taps is possible. 

–  Thermostatic pressure valves must be suitable for hydraulically controlled instantaneous water 

  heaters (see also note "1.6 Recommended adjustment of taps/valves").

  Note:

 

In order for the starting volumes (see Table 3) of stages I and II to be reached safely, pressure losses from 

the instantaneous water heater, tap/valve, hand shower, shower hose and pipework must be taken into 

account during installation. 

Typical pressure losses for a shower water volume of 10 l/min:

  –  Mono level mixer 

0.04 - 0.08 MPa

  –  Thermostatic valves 

03 - 0.05 MPa

  –  Hand shower 

0.03 - 0.15 MPa

•  Always carefully observe all information in these operating and installation instructions. These contain 

important information regarding safety, operation, installation and maintenance of this equipment.

For contractors

2. 

Installation instructions

!

Содержание DDLT PinControl 13

Страница 1: ...ontrol 24 Hydraulisch gesteuerter Durchlauferhitzer Gebrauchs und Montageanweisung Проточный водонагреватель с гидравлическим управлением Инструкция по эксплуатации и установке Hydraulically controlled instantaneous water heater operating and installation instructions ...

Страница 2: ..._________________________ 10 3 3 Gerätemontage vorbereiten____________________ 10 3 4 Aufhängeleiste befestigen _____________________ 10 3 5 Gerätemontage _____________________________ 10 3 6 Wasseranschluss _____________________________ 10 3 7 Elektrischer Anschluss_________________________ 10 3 8 Montage abschließen_________________________ 10 3 9 Erstinbetriebnahme __________________________ 11...

Страница 3: ...3 A B 395 mm 100 mm 485 mm 325 mm 45 mm G 5 mm 93 mm 226 mm 190 mm 50 mm 112 mm 190 mm 35 mm 4 5 a C26_02_02_0763 14 9 3 4 5 6 7 1 2 8 10 11 C26_02_02_0777 14 15 16 17 18 19 20 21 12 13 ...

Страница 4: ...4 C D E G H I 26_02_02_0774 F WW KW 26_02_02_0752 a KW WW C26_02_02_0761 C26_02_02_0780 C26_02_02_0766 b a b a b b 3 6 4 14 a 30 mm 160 mm b 15 11 4 22 5 17 C26_02_02_0784 C26_02_02_0779 a ...

Страница 5: ...5 J L M N 325 mm 50 mm 40 mm 50 mm 26_02_02_0764 ADEo 70 WD 18 Nm C26_02_02_0765 C26_02_02_0781 a 19 a c a C26_02_02_0770 b d e K LR 1 A c b a C26_02_02_0830 24 23 ...

Страница 6: ... Armatur reduzieren 1 3 Sicherheitshinweise Bei Auslauftemperaturen größer 43 C besteht Verbrühungsgefahr Sollten Kinder oder Personen mit eingeschränkten physischen sensorischen oder geistigen Fähigkeiten das Gerät bedienen so ist sicherzustellen dass dies nur unter Aufsicht oder nach entsprechender Einweisung durch eine für ihre Sicherheit zuständige Person geschieht Kinder sollten beaufsichtigt...

Страница 7: ...d voll geöffneter Armatur Kaltwasser am Zweigriff zumischen Einhandmischer Vollleistung Hebel der Armatur ganz nach Warm drehen Armatur voll öffnen Temperaturerhöhung durch langsames Schließen der Armatur Temperaturreduzierung durch Zumischen von kaltem Wasser oder wenn möglich durch weiteres Öffnen der Armatur 1 7 Erste Hilfe bei Störungen Sicherungen überprüfen Armaturen und Duschköpfe auf Verka...

Страница 8: ...einem druckfesten Kunststoffmantel umschlossen Das Heizsystem ist be sonders auch für kalkarme und kalkhaltige Wässer geeignet siehe Tabelle 3 Einsatzbereiche 2 3 Wichtige Hinweise Luft in der Kaltwasserleitung kann das Blankdraht Heizsystem des Gerätes zerstören oder löst das Sicherheitssystem aus Wurde die Wasserzufuhr des Durchlauferhitzers unterbrochen z B wegen Frostgefahr oder Arbeiten an de...

Страница 9: ...ischen elektrischen Widerstand oder die elek trische Leitfähigkeit des Wassers erfahren Sie bei Ihrem Wasserversorgungs Unternehmen Gerätemontage nur im geschlossenen frostfreien Raum Demontiertes Gerät frostfrei lagern da sich im mer Restwasser im Gerät befindet Die Schutzart IP 25 strahlwassergeschützt ist nur mit sachgemäß montierter Kabeltülle gewährleistet Wasserinstallation Werkstoff der Kal...

Страница 10: ...chend dem Werkstoff der Befestigungswand zu wählen befestigen Beiliegenden Gewindebolzen in die Aufhängeleiste schrauben 3 5 Gerätemontage G Doppelnippel eindichten und einschrauben Die Kabeltülle 4 über das Elektroanschlusskabel führen Rückwand über den Gewindebolzen und die Kabeltülle führen die Kabeltülle an den Rasthaken mit Hilfe einer Zange in die Rückwand ziehen und beide Rasthaken hörbar e...

Страница 11: ...ckbegrenzer AP 3 aktivieren Der Durchlauferhitzer wird mit ausgelöstem Sicherheits Druckbegrenzer ausgeliefert Rücksetztaste eindrücken 3 Gerätekappe montieren und hörbar einrasten Überprüfen Sie den festen Sitz der Gerätekappe auf der Rück wand 4 Netzspannung einschalten 5 Arbeitsweise des Durchlauferhitzers prüfen Übergabe des Gerätes Dem Benutzer die Funktion des Gerätes erklären und mit dem Ge...

Страница 12: ...kontakt öffnet beim Einschalten des Durchlauferhitzers Der Lastabwurf erfolgt bei Betrieb des Durchlauferhitzers Das Lastabwurfrelais darf nur an die mittlere Phase der Geräte Netzklemme angeschlossen werden 4 4 AP Armaturen AEG Haustechnik Aufputz Druckarmatur ADEo 70 WD N Bestell Nr 18 39 34 Wasserstopfen G mit Dichtungen a montieren gehören zum Lieferumfang der Druckarmatur ADEo 70 WD Armatur m...

Страница 13: ...se nach EN 60335 1 Schutzart nach EN 60529 IP 25 Prüfzeichen siehe Geräte Typenschild Bauaufsichtliches Prüfzeugnis PA IX xxxx I beantragt Wasseranschluss Außengewinde G Elektroanschluss 3 PE 400 V 50 60 Hz Blankdraht Heizsystem 900 Ωcm siehe Tabelle 4 Kaltwasserzulauftemperatur max 25 C Einsatzgebiet kalkarme und kalkhaltige Wässer 5 2 Einsatzbereiche Spezifischer elektrischer Widerstand und spez...

Страница 14: ...leitung Duschkopf Perlatoren entkalken ggf er neuern Verschmutzung Sieb A 22 reinigen Durchflussmengenregler A 7 Leis tungs Schalteinheit schaltet trotz voll geöffneter Armatur nicht ein Erforderliche Einschaltmenge zum Einschal ten der Heizleistung wird nicht erreicht Sieb A 22 reinigen Gerät erzeugt trotz hörbarem Ein schaltgeräusch des Differenzdruck schalters kein warmes Wasser Der Sicherheits...

Страница 15: ... sich die Schutzart in IP 24 spritzwasser geschützt Rohrbausatz Versatzmontage Best Nr 22 77 02 bestehend aus Universal Montagerahmen Techn Beschreibung siehe Best Nr 22 77 01 Rohrbögen zur vertikalen Verschiebung des Gerätes gegenüber dem Wasseranschluss um 90 mm nach unten Rohrbausatz Gas Wasserheizer Austausch Best Nr 22 77 03 bestehend aus Universal Montagerahmen Techn Beschreibung siehe Best ...

Страница 16: ...ir sämtliche Material und Montagekosten Soweit der Kunde wegen des Garantiefalles aufgrund gesetzlicher Gewährleistungsansprüche gegen andere Ver tragspartner Leistungen erhalten hat entfällt eine Leistungspflicht Soweit eine Garantieleistungen erbracht wird übernehmen wir keine Haftung für die Beschädigung eines Gerätes durch Diebstahl Feuer Aufruhr o ä Ursachen Über die vorstehend zugesagten Gar...

Страница 17: ... Restmülltonne und sind getrennt zusammeln und zu entsorgen Die Entsorgung dieses Altgerätes fällt nicht unter das Gesetz über das Inverkehrbringen die Rücknahme und die umweltverträgliche Entsorgung von Elektro und Elektronikgeräten Elektro und Elektronikgerätegesetz ElektroG und kann nicht kostenlos an den kommunalen Sammelstellenabgegeben werden Das Altgerät ist fach und sachgerecht zu entsorge...

Страница 18: ...18 Notizen ...

Страница 19: ...19 Notizen ...

Страница 20: ...ormation_ _________________ 28 3 2 Installation site_______________________________ 28 3 3 Preparing the device installation_ ________________ 28 3 4 Fitting the mounting bracket__________________ 28 3 5 Equipment installation_ ______________________ 28 3 6 Water connection__________________________ 28 3 7 Power supply_________________________________ 28 3 8 Completing the installation_ __________...

Страница 21: ...21 A B 395 mm 100 mm 485 mm 325 mm 45 mm G 5 mm 93 mm 226 mm 190 mm 50 mm 112 mm 190 mm 35 mm 4 5 a C26_02_02_0763 14 9 3 4 5 6 7 1 2 8 10 11 C26_02_02_0777 14 15 16 17 18 19 20 21 12 13 ...

Страница 22: ...22 C D E G H I 26_02_02_0774 F DHW CW 26_02_02_0752 a KW DHW C26_02_02_0761 C26_02_02_0780 C26_02_02_0766 b a b a b b 3 6 4 14 a 30 mm 160 mm b 15 11 4 22 5 17 C26_02_02_0784 C26_02_02_0779 a ...

Страница 23: ...23 J L M N 325 mm 50 mm 40 mm 50 mm 26_02_02_0764 ADEo 70 WD 18 Nm C26_02_02_0765 C26_02_02_0781 a 19 a c a C26_02_02_0770 b d e K LR 1 A c b a C26_02_02_0830 24 23 ...

Страница 24: ...e the water volume flow rate at the tap 1 3 Safety information There is a risk of scalding at outlet temperatures in excess of 43 C Where children or persons with limited physical sensory or mental capabilities are to be allowed to control this equipment ensure that this will only happen under supervision or after appropriate instructions by a person responsible for their safety Children should be...

Страница 25: ...n lever tap if the temperature is too high and the valve is fully open Mono lever tap Full load Turn the tap lever fully towards Hot Fully open the valve Raise the temperature by slowly closing the valve Reduce the temperature by admixing cold water or if possible by opening the valve further 1 7 First aid in case of faults Check all fuses Check taps valves and shower heads for scaling or contamin...

Страница 26: ...et The heating system is also particularly suitable for water with low limescale or with limescale content see Table 3 Application areas 2 3 Important information Air in the cold water supply can destroy the bare wire heating system inside the equipment or can trip the safety system If the water supply to the instantaneous water heater has been interrupted e g because of a risk of frost or work on...

Страница 27: ...ll advise you of the specific electrical water resistance or conductivity Install the device only in an enclosed room free from the risk of frost Store the dismantled device in a room free from the risk of frost as water residues remain inside the device The protection IP 25 hoseproof can only be ensured with a correctly fitted cable grommet Water installation Material of the cold water line Steel...

Страница 28: ...lugs not part of the standard delivery select in accordance with the material of the fixing wall Insert the studs supplied into the mounting bracket 3 5 Equipment installation G Seal in and insert the twin nipples Push the cable grommet 4 over the power cable Slide the back panel over the studs and the cable grommet pull the cable grommet with a pair of pliers against the locking hooks and let bot...

Страница 29: ...ety pressure limiter AP 3 The instantaneous water heater is delivered with the safety pressure limiter triggered press the reset button 3 Fit and audibly let the device cap click into place Check that the device cap is firmly seated on the back panel 4 Switch on the mains power 5 Check the instantaneous water heater function Equipment handover Explain the equipment function to the user and familia...

Страница 30: ... the instantaneous water heater starts Only connect the automatic maximum demand controller to the central phase of the equipment terminals mains power 4 6 Taps for finished walls AEG Haustechnik pressure tested tap for finished walls ADEo 70 WD N part no 18 39 34 Fit plug G with gaskets a part of the standard delivery of the pressure tested tap ADEo 70 WD Fit the tap Insert the support plate into...

Страница 31: ...level to EN 60529 IP 25 Test symbols see equipment type plate Building Regulation test certificate Germany PA IX xxxx I applied for Water connection male thread G Power connection 3 PE 400 V 50 60 Hz Bare wire heating system 900 Ωcm see Table 4 Cold water inlet temperature max 25 C Applications water with low limescale levels and with limescale content 5 2 Application areas Specific electrical res...

Страница 32: ...nd if required replace shower head perlator Contamination Clean sieve A 22 Throughput volume controller A 7 output switch unit will not start in spite of tap being fully opened The start up volume required to start the heater has not been reached Clean sieve A 22 No hot water in spite of audible sound of the differential pressure switch starting Safety pressure limiter AP 3 has switched the device...

Страница 33: ...fset installation set for unfinished walls Part no 22 77 02 Comprising Universal mounting frame for specification see part no 22 77 01 Pipe bends for a vertical offset of the device relative to the water connection by 90 mm downwards Pipe assembly replacement of a gas fired water heater Part no 22 77 03 Comprising Universal mounting frame for specification see part no 22 77 01 Pipe bends for the i...

Страница 34: ...uld be carried out by a qualified installer The company does not accept liability for failure of any goods supplied which have not been installed and operated inaccordance with the manufacturer s instructions Environment and recycling Recycling of obselete appliances Appliances with this label must not be disposed off with the general waste They must be collected separately and disposed off accord...

Страница 35: ...35 Notes ...

Страница 36: ...ния по монтажу__________________ 43 3 2 Место монтажа_____________________________ 43 3 3 Подготовка к монтажу устройства______________ 43 3 4 Закрепление планки для подвешивания ________ 43 3 5 Монтаж устройства _ ________________________ 43 3 6 Соединение для подачи воды _________________ 43 3 7 Подключение к электрической сети_____________ 43 3 8 Завершение монтажа________________________ 44 3 ...

Страница 37: ...37 A B 395 mm 100 mm 485 mm 325 mm 45 mm G 5 mm 93 mm 226 mm 190 mm 50 mm 112 mm 190 mm 35 mm 4 5 a C26_02_02_0763 14 9 3 4 5 6 7 1 2 8 10 11 C26_02_02_0777 14 15 16 17 18 19 20 21 12 13 ...

Страница 38: ...38 E G H I 26_02_02_0774 WW KW 26_02_02_0752 a C26_02_02_0761 C26_02_02_0780 C26_02_02_0766 b a b a b b 3 6 4 14 a 30 mm 160 mm b 15 11 4 22 5 17 C26_02_02_0784 C26_02_02_0779 a KW WW C F D ...

Страница 39: ...39 c b a C26_02_02_0830 J L M N 325 mm 50 mm 40 mm 50 mm 26_02_02_0764 ADEo 70 WD 18 Нм C26_02_02_0765 C26_02_02_0781 a a 19 a c a C26_02_02_0770 b d e K LR 1 A 24 23 ...

Страница 40: ...чество воды на водопроводной арматуре 1 3 Указания по технике безопасности При температуре на выходе больше 43 C существует опасность ошпаривания Если устройством пользуются дети или лица с ограниченными физическими сенсорными или умственными способностями то необходимо обеспечить чтобы это происходило только под надзором или после соответствующего инструктажа со стороны лица которое несет ответст...

Страница 41: ...полностью открытой арматуре подмешивать воду на кране с двумя ручками Одноручный смеситель Полная мощность Повернуть рычаг арматуры полностью в положение Горячая вода Полностью открыть арматуру Повышение температуры из за медленного закрытия арматуры Снижение температуры путем подмешивания холодной воды или если возможно путем дальнейшего открытия арматуры 1 7 Первая помощь при неполадках Проверит...

Страница 42: ...ные Неизолированная нагревательная система окружена герметичной пластмассовой оболочкой Система нагрева подходит как для жесткой так и для мягкой воды см таблицу 3 Области применения 2 3 Важные указания Воздух в линии подачи холодной воды может разрушить неизолированную нагревательную систему Его наличие также может привести к срабатыванию системы безопасности При прерывании подачи воды к проточно...

Страница 43: ... электрическую проводимость воды вы можете узнать у водоснабжающего предприятия Монтаж устройства выполнять только в закрытом незамерзающем помещении Демонтированное устройство хранить в незамерзающем месте поскольку в нем всегда остается вода Степень защиты IP 25 защита от струящейся воды обеспечивается только при надлежащей установке наконечника кабеля Подвод воды Материал линии подачи холодной ...

Страница 44: ...нки Закрутить прилагаемый резьбовой болт в планку для подвешивания 3 5 Монтаж устройства G Герметизировать и закрутить двойной ниппель Провести наконечник кабеля 4 через кабель подключения к электросети Провести заднюю стенку через резьбовой болт и кабельный наконечник кабельный наконечник возле крючков с помощью клещей протянуть в заднюю стенку и зафиксировать оба крючка должен быть щелчок Придав...

Страница 45: ...раничитель давления AP 3 Проточный водонагреватель поставляется со сработавшим предохранительным ограничителем давления вдавить кнопку сброса 3 Смонтировать колпак устройства и зафиксировать со слышимым щелчком Проверьте прочность посадки колпака на задней стенке 4 Включить сетевое напряжение 5 Проверить работу проточного водонагревателя Передача устройства Объясните пользователю как функционирует...

Страница 46: ...очного водонагревателя Сброс нагрузки происходит при эксплуатации проточного водонагревателя Реле сброса нагрузки можно подключать только к средней фазе сетевой клеммы устройства 4 4 Арматура AP AEG Haustechnik напорная арматура для установки поверх штукатурки ADEo 70 WD N для заказа 18 39 34 Смонтировать пробку G с уплотнениями a входят в комплект поставки напорной арматуры ADEo 70 WD Смонтироват...

Страница 47: ...ласно DIN EN 60335 1 Степень защиты согласно EN 60529 IP 25 Знак технического контроля см заводскую табличку устройства Акт испытаний стройнадзора PA IX xxxx I заявлен Подключение для подачи воды внешняя резьба G Электрическое соединение 3 PE 400 В 50 60 Гц Неизолированная нагревательная система 900 Ω см см таблицу 4 Температура подачи холодной воды макс 25 C Область применения мягкая и жесткая во...

Страница 48: ...при необходимости заменить Загрязнение Очистить фильтр A 22 Регулятор расхода A 7 блок переключения мощности не включается хотя арматура открыта полностью Не достигается количество необходимое для включения водонагревателя Очистить фильтр A 22 Хотя слышен звук включения переключателя дифференциального реле давления устройство не подает горячую воду Предохранительный ограничитель давления AP 3 из с...

Страница 49: ... защиты изменяется на IP 24 защита от брызг Монтаж набора труб для заказа 22 77 02 компоненты универсальная монтажная рамка техн описание см для заказа 22 77 01 колена трубы для вертикального перемещения устройства в отношении линии подачи воды на 90 мм вниз Набор труб для замены газового водонагревателя для заказа 22 77 03 компоненты универсальная монтажная рамка техн описание см для заказа 22 77...

Страница 50: ...ра первый ввод в эксплуатацию и обслуживание могут проводиться только компетентным специалистом в соответствии с данной инструкцией Не принимаются претензии по неисправностям возникшим вследствие неправильной установки и эксплуатации прибора Довкілля та переробка відходів Утилізація старих приладів Прилади з таким маркуванням не слід утилізувати разом із побутовим сміттям Їх слід збирати окремо та...

Страница 51: ...51 Для заметок ...

Страница 52: ...strzeżone zmiany techniczne i ewentualne błędy Omyly a technické změny jsou vyhrazeny A muszaki változtatások és tévedések jogát fenntartjuk Boэможность неточностей и технических изменений не исключается Hungary Stiebel Eltron KFT Pacsirtamező u 41 1036 Budapest Tel 01 2506055 Fax 01 3688097 Nederland Stiebel Eltron Nederland b v Divisie AEG Home Comfort Daviottenweg 36 Postbus 2020 5222 BH s Hert...

Отзывы: