Securing the appliance to the cabinet
Electrical installation
The manufacturer is not responsible if you do not obey the safety precautions from chapter
"Safety".
This appliance is only supplied with a main cable.
Applicable types of cables for Europe:
• Minimum size Cable/flex: 1,5mm²
• Cable/ flex type: H07 RN
-
F, H05 RN
-
F, H05 RRF, H05 VV
-
F, H05 V2V2
-
F (T90), H05 BB
-
F
• Fuse 13 A
Applicable types of cables for UK only
Connection via
Min. size Cable/flex
Cable/flex type
Fuse
• 13 A socket outlet
• 13 A spur box
2,5 mm²
Three core butyl insulated
13 A min.
Oven Control Circuit
2,5 mm²
PVC/PVC twin and earth
15 A min.
20 A min.
ENVIRONMENT CONCERNS
The symbol on the product or on its packaging indicates that this product may not be
treated as household waste. Instead it should be taken to the appropriate collection point
for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences for the
A