6
6. Installation location
The unit is to be installed in a
closed, frost-free room (discon-
nected units are to be stored in a frost-free
location, since there will always be some
water left in the unit).
The BMU si to be installed vertically on a
wall (hot water connection downwards).
Warning!
When selecting the temperature
at the draw off fitting, high water
temperatures may be reached. Children,
especially, should be kept from the fitting
due to the risk of scalding.
The unit must be earthed (see
ciucuit diagram). To protect
against water penetration, the cable seal
(8) must be used.
7. Installing the unit
1. Flush the cold water pipe thoroughly.
2. Fit a secure connection cable
(ensure dimensions are correct).
3. Release cover securing screw.
4. Remove cover.
5. Deltermine the position of the drillholes
and drill the holes. Insert the wall plugs
and screw in the screws (ensure screw
insertion depth is correct) (10).
6. Feed the connection cable through the
cable seal (8) in the rear wall. Guide the
unit over the wall securing screws and
slide it downwards.
7. Fit the filter and the washer (11) to the
cold water inlet of the unit (5). Tighten
the union nut to the warm water outlet
of the unit. (6)
8. Straighten the unit and tighten the screws.
9. Connect the electrical supply.
10. Fit the cover and secure with the screw.
11. Turn the rotary control to the left and
right (internal setting lever will engage).
8. First operation (Only to be carried out
by a qualified installer)
Before switching on, set the
rotary temperature control to
“OFF”. Open water valve until the pipe-
work and the unit are free of air.
- Check the operation of the water heater.
Warning
: Open hot water faucet
for a few minutes until water
flow is continuous and all air is purged
from water pipes. The unit’s plastic cover
must be installed before the circuit breaker
is turned on.
Handing over the unit
Explain to the user how the unit works and
familiarise him or her with its use.
- Advise the user about possible hazards
(high water temperature)
- Hand over these instructions, to be
kept in a safe place.
9. Service note
When carrying out any work,
isolate the unit from the mains
and shut off the water connection.
- Clean the filter
Disconnect the union nut, remove
washer, filter (11) and clean.
Re-assemble in reverse order.