23
Installation Instructions
INSTALLATION INSTRUCTIONS
Attention:
The new appliance may only be installed and connected by a
registered
expert
in according with the rules and law provisions in force and in accordance with
these instructions.
Please comply with this. If you do not, any damage resulting is not covered by the
warranty.
Check that unit voltage and power, marked on the rating plate applied on the
appliance, are correct for the supply.
Fixed wired installations are to be provided with suitable isolation means in accordance
with the said rules.
IMPORTANT
WARNING
This appliance must be earthed
The supply cable not comes in contact with any component the temperature of which
exceed the ambient temperature by 50 °C and with sufficient length for allowing
any subsequent removal of the unit.
Easy access to the plug or the switch is ensured once the appliance is installed.
Ensure that there is sufficient cable allowed for any subsequent removal of the unit.
Use cable Mod. H05RR-F 3 x 1.5 sq. mm
WARNING
If an fixed appliance is not equipped with supply cable and plug, the power supply
must be fitted with a disconnect switch in which the distance between contacts
permits total disconnection in accordance with overvoltage category III, as required
by installation regulations.
Be sure that the earth wire green/yellow is not interrupted by the switch.
The wires in the mains lead are coloured in
accordance with the following code:
GREEN
&
YELLOW................................EARTH
BLUE .......................................................NEUTRAL
BROWN ..................................................LIVE
Open the mains terminal block cover as
shown, unscrew the cable clamp and unscrew
(not fully) the screws in the mains terminal
block which secure the three wires of the
mains cable . Fit the cable and refit the
cable clamp.
Live
Neutral
Cable
clamp
All manuals and user guides at all-guides.com