--------------------------------------------------------------------------------38/50--------------------------------------------------------------------------------
PARAMETER 2
FUNCTION
1 character
block
PARAMETER 3
FUNCTION
8 characters
value
PARAMETER 4
FUNCTION
2 characters
optional address
5.5.11
RQ – request
The RQ command answers the type of the detected transponder.
Input format:
RQ
<SP>
parameter
<CR>
Output (example):
ACK
<CR>
Parameters:
PARAMETER
FUNCTION
0
non halt transponders
1
all transponders
5.5.12
SE – select
The command SE selects that transponder that answered at the anticollision. For ultralight and DESFire
transponders it is select level 1 command.
Input format:
SE
<CR>
Output (example):
ACK
<CR>
5.5.13
SE2 – select level 2
The command SE2 selects that transponder that answered at the anticollision level 2. For ultralight and
DESFire transponders it is select level 2 command.
Input format:
SE2
<CR>