Manual ACM 9 - ARE i9 release
Version: 10
Page: 16 / 51
Manual ACM9_ARE i9 release V10.docx
3.1.4
Transponder orientation relative to ARE i9
Disk parallel (recommended)
Glass transponder perpendicular (recommended)
Direction of travel
The highest read range is achieved right above the center of ARE i9 front side.
Disk Perpendicular
Glass parallel
Direction of
travel
In this orientation both transponder types are read best just outside the perimeter of ARE i9. There is a significantly
reduced read range in the center of ARE i9. This is no problem in a dynamic situation. Please ensure to start reading before
the transponder is above ARE i9 and keep reading until the transponder is beyond ARE i9.
Reading distance depends a lot on the particular installation. Absolute values only make sense based on a particular
transponder. Absolute values make no sense for transponder types, because the values will vary too much. Above is the
guiding principles to achieve the best possible read range.