26
A device must be provided in the electrical installation which allows the
appliance to be disconnected from the mains at all poles with a contact
opening width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw
type fuses are to be removed from the holder), earth leakage trips and
contactors.
Sticking the seal in the rabbet
•
Clean the rabbet in the work surface.
•
Stick the one-sided self-adhesive sealing tape supplied onto the up-
per surface of the rabbet along the edges of the cut-out section.
–
Cut the sealing tape into four pieces relating to the length of the
edges of the rabbet.
–
For the four corners of the rabbet the ends of the sealing tapes
must be cut into mitres. Do not stick the ends over one another.
–
Stick the sealing tape flush into the corner of the rabbet, so that no
silicon compound can get under the glass ceramic when grouting.
–
Don’t stretch the tapes when sticking them on.