you change from natural gas 13 mbar
2)
to natural gas 20 mbar to tighten the by-pass
screw about 1/4 of a turn (1/2 of a turn for Triple Crown burner).
1
1
Minimum adjustment screw
5. Make sure the flame does not go out when you quickly turn the knob from the maxi
-
mum position to the minimum position.
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on the rating plate agree with the
voltage and the power of the local power supply.
• This appliance is supplied with a mains cable. It has to be supplied with a correct plug,
able to support the load marked on the identification plate. The plug has to be fitted in a
correct socket.
• Any electrical component must be installed or replaced by the Service Force Centre tech
-
nician or qualified service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug after installation.
• Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.
• The appliance must not be connected with an extension cable, an adapter or a multiple
connection (risk of fire). Check that the ground connection is in conformity with the
standard and regulations force.
• The power cable must be placed in such a way that it does not touch any hot part.
• Connect the appliance to the mains with a device that lets to disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm, eg. auto
-
matic line protecting cut-out, earth leakage trips or fuse.
• None of a parts of the connection cable can not get a temperature 90 °C. The blue neu
-
tral cable must be connected to the terminal block label with "N". The brown (or black)
phase cable (fitted in the terminal block contact marked with "L") must always be con
-
nected to the live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that
the cable section is applicable to the voltage and the working temperature. The yellow/
green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.
Installation
23
Содержание 65857G-M
Страница 67: ...67 ...
Страница 68: ...www aeg electrolux com shop 397174701 A 412010 ...