![AEG 222388 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/aeg/222388/222388_operation-and-installation_16239029.webp)
29
Installation – for qualified contractors
|
Guarantee – Environment and recycling
15.8
Data table
DDLE Basis
11
DDLE Basis 13
DDLE Basis 18
DDLE Basis 18/21/24
DDLE Basis
27
229296
229297
222388
222390
222391
Electrical data
Rated voltage
V
380
400
380
400
415
380
400
415
380
400
415
380
400
Rated output
kW
10.1
11 12.2 13.5 14.5 16.2
18 19.4 16.2/19/21.7 18/21/24 19.4/22.6/25.8 24.4
27
Rated current
A 15.4
16 18.5 19.5 20.2 24.7
26
27 27.6/29.5/35 29/31/35 30.1/32.2/36.3
37.1
39
Fuse
A
16
16
20
20
20
25
25
32
32/32/35 32/32/35
32/32/40
40
40
Phases
3/PE
3/PE
3/PE
3/PE
3/PE
Frequency
Hz 50/60 50/60 50/60 50/60
50/- 50/60 50/60
50/-
50/60
50/60
50/- 50/60 50/60
Specific resistance ρ
15
≥ (at ϑcold ≤25 °C)
Ω cm
900 900 900 900 1000 900 900 1000
900
900
1000 900 900
Specific conductivity
σ
15
≤ (at ϑcold ≤25 °C)
μS/cm
1111 1111 1111 1111 1000 1111 1111 1000
1111
1111
1000 1111 1111
Specific resistance ρ
15
≥ (at ϑcold ≤45 °C)
Ω cm
1200 1200 1200 1200 1300 833 1200 1300
833
1200
1300 833 1200
Specific conductivity
σ
15
≤ (at ϑcold ≤45 °C)
μS/cm
830 830 830 830 770 1200 833 770
1200
833
770 1200 833
Max. mains imped-
ance at 50Hz
Ω
0.379 0.360 0.347
0.284
0.270
0.260 0.254 0.241
Connections
Water connection
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Application limits
Max. permissible
pressure
MPa
1
1
1
1
1
Max. inlet temperature
for reheating
°C
45
45
45
45
45
Values
Max. permissible inlet
temperature
°C
60
60
60
60
60
On
l/min
>3
>3
>3
>3
>3
Flow rate for pressure
drop
l/min
3.1
3.9
5.2
5.2/6.0/6.9
7.7
Pressure drop at flow
rate
MPa
0.07 (0.02
without
DMB)
0.11 (0.03 without
DMB)
0.08 (0.06 without
DMB)
0.08/0.10/0.13 (0.06/0.08/0.10 without
DMB)
0.16(0.12
without
DMB)
Flow rate limit at
l/min
4.0
4.0
8.0
8.0 / 8.0 / 9.0
9.0
DHW delivery
l/min
5.6
6.9
9.2
9.2/10.7/12.3
12.7
Δϑ on delivery
K
28
28
28
28
28
Hydraulic data
Nominal capacity
l
0.4
0.4
0.4
0.4
0.4
Versions
Connected load ad-
justable
-
-
-
X
-
Temperature setting
range
°C
ca. 30-60
ca. 30-60
approx. 30-60
approx. 30-60 approx. 30-
60
Insulating block
Plastic
Plastic
Plastic
Plastic
Plastic
Heating system heat
generator
Bare wire
Bare wire
Bare wire
Bare wire
Bare wire
Cover and back panel
Plastic
Plastic
Plastic
Plastic
Plastic
Colour
White
White
White
White
White
IP rating
IP25
IP25
IP25
IP25
IP25
Dimensions
Height
mm
485
485
485
485
485
Width
mm
226
226
226
226
226
Depth
mm
93
93
93
93
93
Weights
Weight
kg
3.6
3.6
3.6
3.6
3.6
GUARANTEE
ENVIRONMENT AND RECYCLING
Guarantee
The guarantee conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.
Guarantee
The guarantee conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use,
dispose of the various materials in accordance with national
regulations.
Содержание 222388