DISPLAy CODES
Code Function
LED
Alarm Description
AA
Self-test
-
The voltage converter is performing a self-test.
The display will switch off after a brief period.
F1
undervoltage protec-
tion
x
Input voltage drops below 9.5 V �0.3 V.
The voltage converter stop inverting power and the external
device will be switched off. If the voltage rises to over 12 V �0.5 V,
the voltage converter will resume normal operation.
F2
Overvoltage protection
x
Input voltage rises over 16 V �0.3 V.
The voltage converter stops inverting power and the external
device will be switched off. If the voltage drops below 14 V �0.5 V,
the voltage converter will resume normal operation.
F3
Overload protection
x
Connected load is above the maximum output power (see „Tech-
nical Data“).
The voltage converter stops inverting power and the external
device will be switched off.
F4
Overheat protection
x
The housing temperature is above 60 ° C.,
If the temperature drops below 45 ° C, the voltage converter
resumes normal operation.
F5
Short-circuit protection
x
The connected device caused a short-circuit.