AEG Electrolux DD8623 Скачать руководство пользователя страница 5

65

• It is advisable to apply for authorization from the relevant controlling

authority when connecting the outlet to an unused chimney flue or
combustion gas duct.
The air outlet installation must comply with the regulations laid down
by the relevant authorities.

• When the unit is used in its extractor version, a sufficiently large

ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.

• National and regional building regulations impose a number of

restrictions on using hoods and fuel-burning appliances connected to
a chimney, such as coal or oil room-heaters and gas fires, in the
same room.

• Hoods can only be used safely with appliances connected to a

chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approximately
500-600 cm

 large to avoid the possibility of a depression being

created during operation of the hood.

• If you have any doubts, contact the relevant controlling authority or

building inspector’s office.

• Since the rule for rooms with fuel burning appliances is “outlet hole of

the same size as the ventilation hole”, a hole of 500-600 cm

2

, which

is to say a larger hole, could reduce the performance of the extractor
hood.

• If the hood is used in its filtering function, it will operate simply and

safely in the above conditions without the need for any of the
aforementioned measures.

• When the hood is used in its extractor function, the following rules

must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
    always follow a gentle curve only
— keep the hose as large as possible (preferably the same diameter
as the outlet hole).

• Failure to observe these basic instructions will drastically reduce the

performance and increase the noise levels of the extractor hood.

Содержание DD8623

Страница 1: ...ube Afzuigkap Hotte aspirante Cooker Hood Cappa aspirante Montage und Gebrauchsanweisung Installatie en gebruiksaanwijzing Manuel de montage et d utilisation Operating and Installation Instructions Is...

Страница 2: ...62 Printed on recycled paper AEG putting words into action...

Страница 3: ...ease filter 67 Led indicator for active carbon filter 67 Resetting the saturation indicator 67 Maintenance and care 68 Metal grease filter 68 Open the metal grease filter 68 Charcoal filter 69 Changin...

Страница 4: ...the hood and replace the filter at the recommended intervals Failure to do so could cause grease deposits to build up resulting in a fire hazard for the installer When used as an extractor unit the ho...

Страница 5: ...ge to avoid the possibility of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule f...

Страница 6: ...n see Special Accessories The air is discharged to the outside through a pipe which must be fitted to connection flange D Fig 1 In order to obtain the best performance the hose should have a diameter...

Страница 7: ...rned to the kitchen through the top grill of the outlet pipe You will need an original AEG KF20 charcoal filter for the filtering function See Special Accessories Fix the deflector using 4 screws 2 9x...

Страница 8: ...of the grease saturation for the filter flashing indicator D Indicates speed 2 LED and indication of the active carbon saturation for the filter flashing indicator E Indicates speed 3 F Indicates Int...

Страница 9: ...fter the LED indicator for the active carbon filter D will activate at this point the saturation detection has been enabled To switch off the saturation detection depress and hold the A and B buttons...

Страница 10: ...en extract the filter pulling downwards Fig 3 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the proce...

Страница 11: ...ck on the filter and later causes bad odours To reactivate the charcoal the filter should be dried in an oven for 10 minutes with a temperature of maximum 100 C After approximately three years of use...

Страница 12: ...or or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp...

Страница 13: ...to do so will cause grease deposits to build up that could constitute a fire hazard Special accessories Charcoal filter KF20 942 120 600 Technical assistance service You are welcome to telephone our...

Страница 14: ...ed agent AEG reserves the right to stipulate the place of the repair i e the customer s home place of installation or AEG workshop 4 The guarantee or free replacement includes both labour and material...

Страница 15: ...details of your new home They will then ensure that the localServiceOrganisationisawareofyourmoveandabletolookafteryouand yourappliances France Senlis 33 0 44 62 29 29 Germany N rnberg 49 0 911 323 26...

Страница 16: ...5 W Motor absorption 130 W 130 W Lighting 2 x 20 W 4 x 20 W Lenght of the cable 150 cm 150 cm Mounting accessories included 1 deflector 1 chimney support 1 support bracket 1 reduction flange 125 120 m...

Страница 17: ...tance of at least 3mm between contacts must be provided This disconnector may be for example a switch fuses plug fuses must be removed from the fuse box fault current switches and remote switches with...

Страница 18: ...s 10 Drill two holes 8mm on the upper side close to the ceilling fit two wall plugs 11 In case the hood is to be used in filter version mount the deflector F on the chimney support with four screws 2...

Страница 19: ...79 17b 17b 4 13 4 13 1 2 3 11 11 12 15 17a 17a 65 16 B G H 8 8 18 F 9 10 14 7 9 10 14 7 5 6 F G 19 19 Fig 6 DD 8623 DD 8623...

Отзывы: