69
Wall unit mounting - Fig. 7
Remove the panels and the grease filter (see paragraphs Removing
the panels and Removing the metal grease filter).
Mark the wall with a centre line, this will aid mounting procedure
(1)
,
position the template so that the mid line printed on the template
matches with the centre line previously drawn, the lower side of the
template corresponds to the lower side of the hood once mounted
(2)
.
Drill two holes Ø 8mm and fix the support bracket with two wall
plugs and screws
(3)
. Hang the hood
(4)
and adjust its position
(5-
6)
.
From the inside of the hood sign 1 point for definitive fixing
(7)
.
Remove the hood
(8)
and drill 1 hole Ø 8mm
(9)
, fit two wall plugs
(10)
.
Drill two holes Ø 8mm on the upper side close to the ceilling, fit two
wall plugs
(11)
(In case the hood is to be used in
filter version
,
mount the deflector
F
on the chimney support with 2 screws) and fix
the chimney support
G
with two screws
(12)
.
Hang the hood again
(13)
and fix it definitively with 1 screw
(14)
.
Fit an exhausting pipe
(15)
to connect the outlet hole
B
of the hood
to the outside (Extractor hood) or to the deflector
F
(Filter version).
Make electrical connection
(16)
.
Fix the chimney first up
(17a)
to the chimney support
(17b)
, then
slide the lower section of the chimney down into the proper housing
on top of the hood
(18)
.
Fix the lower section to the hood with two screws
(19)
.
Refit the grease filter and the panels.
Note! Check that the upper halogen lamps are not covered (e.g. by
the wall units).